The best hatch rates can be reached with which parameter combination is not known for different species yet. Cimuka Research Team is collecting
data from our research center and customers for different APC applications. The table below outlines the recommended parameters for
cooling for a set (clS) mode.
Note: Cooling by a time (clt) mode is highly dependent on hatchery room conditions and the number of eggs in the model. It is only advisable to use
for temperature controlled hatchery rooms to reach same hatching results.
Active Periodic Cooling (APC) Parameters
Cooling mode
Cooling start time
Cooling cycle time
Cooling set point C ( set –adjusted data)
Cooling set point F ( set –adjusted data)
Waiting time in cooling set point
Max cooling time
Humidification*
Humidification Time*
Max humidity during humidification*
Cooling fan activation**
* only for models equipped with humidifier
**only for models equipped with cooling fan
CAUTION!
Turn off Active Periodic Cooling (APC) function during hatching period - Last 2-3 days of incubation. Cooling in last 2-3
days of incubation results in bad hatching rates and chick loss.
CAUTION!
Changing cooling mode (cIF) or cooling cycle time (cPr) parameters in APC menu resets periodic cooling cycle time (cPr).
CAUTION!
In clS mode, time to reach cooling set point cSt (Fst) is highly dependent on room temperature. For very low set points,
system may not be able to reach cooling set point. For such situations, system finalizes cooling at max cooling time (hct).
Display
Factory settings
clF
oFF
cb
cof
cPr
24 h
cSt
-8.0 C
FSt
-15.0 F
cth
20 min
10 minutes 8th to 13th
20 minutes 14th to 18th
hct
120 min
chu
on
cht
10 min.
chh
80 RH%
cFn
on
20
Chicken
Duck
cIS
cIS
On at 8th day
On at 8th day
Off at 19th day
Off at 25th day
con
con
24
24
-8.0
-8.0
-15.0
-15.0
10 minutes 8th to 15th
25 minutes 16th to 25th
120 minutes
150 minutes
-/on
on
10
15
80
80
on
on
Goose
cIS
On at 8th day
Off at 27th day
con
24
-8.0
-15.0
10 min. 8th to 14th
20 minutes 15th to 21th
40 minutes 22th to 27th
180 minutes
on
15
80
on