CT SERIES
37.7
T
U
50
D
H
%
hhı
T
U
10
D
H
%
hlo
T
U
-10
D
H
%
(f)thi
T
U
0,8
D
H
%
(f)tlo
T
U
-2.0
D
H
%
(f)tco
T
U
0.0
D
H
%
hco
T
U
0.0
D
H
%
User Menu Parameters
Hold T + H together for 3 seconds to enter menu.
-Use T /H buttons to choose parameter
-Use U/D buttons to change parameter values
-Hold T + H together for 3 seconds to save changes
hhi: high humidity alarm.
Started : set value +10
Delay time: 20 minutes
Notification: Alr 5
Voice alarm : continuous
hlo: low humidity alarm.
Started : set value -10
Delay time: 20 minutes
Notification: Alr 6
Voice alarm : intermittently
(f)thi: high temperature alarm.
Started : set value + 0,8
Delay time: 2 minutes
Notification: Alr 1/3
Voice alarm : continuous
(f)tlo: low temperature alarm.
Started : set value - 2.0
Delay time: 30 minutes
Notification: Alr 2/4
Voice alarm : intermittently
tco: temperature calibration value.
CAUTION!
tCo is a critical parameter . Changing this can
results in chick looses. Plsease use qualified and
calibrated
glass
or
electronic
thermometers
calibration purpose. Check temperature values regularly.
hco: humidity calibration value.
CAUTION!
hCo is a critical parameter. Changing this can
results in chick looses. Please use qualified and
calibrated
glass
or
electronic
thermometers
calibration purpose. Check humidity values regularly.
uS2
T
U
th
D
H
%
(f)rtl
T
U
18
D
H
%
(f)rth
T
U
28
D
H
%
rhl
T
U
10
D
H
%
rhh
T
U
85
D
H
rAt
T
U
for
off
D
H
%
rAh
T
U
for
off
D
H
%
10
US2: USB connected device
no : no connected device
th : second sensor connected ( room/calibration)
ıot: iot module connected
Notification: Alr 15 (usb connection error)
below parameters active if Us2 is selected "th"
(f)rtl: second sensor low temperature alarm.
Started : below 18 C / 65 F
Delay time: no
Notification: Alr 10
Voice alarm : intermittently
(f)rth: second sensor high temperature alarm.
Started : over 28 C / 83 F
Delay time: no
Notification: Alr 9
Voice alarm : intermittently
rhl: second sensor low humidity alarm.
Started : below 10 RH
Delay time: no
Notification: Alr 14
Voice alarm : intermittently
rhh: second sensor high humidity alarm.
Started : over 85 RH
Delay time: no
Notification: Alr 13
Voice alarm : intermittently
rAt: second sensor temperature alarm activation.
On: alarms activated
Off: alarms deactivated
rAt: second sensor humidity alarm activation.
On: alarms activated
Off: alarms deactivated