Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
The hot and cold supplies must be of equal
pressures.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 27.
Operation 11XXX/171XXX/71XXX
By turning the handle on the left hand side the
thermostatic mixer is opened, closed and the flow
can be changed from tub to shower function.
The temperature is selected by turning the graduated
handle on the right side.
Operation 11XXX/171XXX/71XXX/
9XXX
The mixer is operated by turning the handle on the
left hand side. The temperature is selected by turning
the graduated handle on the right side.
Temperature limitation
The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Attention!
The mixer is equipped with non return valves.
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with national
or regional regulations (at least once a year)
10
English
Using the Thermostatic mixer in conjunction
with combination boilers.
If fitting a hand shower remove the water limiter
from the shower.
Technical Data
Operating pressure:
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0.3 MPa:
(1 MPa = 10 bars = 147 PSI)
Test certificate 16241XXX /
17241XXX / 37241XXX:
Anti-pollution function
Spare parts (see page 4 - 5)
1
thermoelement
2
shut off and diverter unit
3
knob for thermoelement
4a
knob for shut off and
diverter unit Carlton
4b
knob for shut off and
diverter unit Terrano
4c
knob for shut off and
diverter unit Citterio
4d
knob for shut off and
diverter unit Montreux
5
aerator cpl.
6
non return valve
7
noise reduction
8
s-unions
9
escutcheon
10
escutcheon Montreux
11
safety set for temperature control 95041000
12
shut off unit
13
filter packing
XXX = Colours
000 chrome plated
090 chrome plated / gold plated
420 platinum
810 satinox
820 brushed nickel
830 polished nickel
max. 1 MPa
1.6 MPa
max. 80° C
65° C
20 l/min
WRAS
94282000
96509000
39398XXX
17396XXX
37395XXX
39397XXX
16396XXX
13485000
96737000
96429000
94140000
96467XXX
98595XXX
94149000
96922000