Maintenance Plan; Standard Delivery - Solo 453 Manual Del Usuario

Pulverizador a presión
Ocultar thumbs Ver también para 453:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
5 Maintenance, cleaning and storage / 6 Standard delivery

5.7 Maintenance plan

Entire pressure sprayer
Hoses and their screw
connectors
Spraying agent tank
Nozzles and
filter element
Pump gasket
Never start working if there are any irregularities or leaks, if you can see any damage to the equipment or
if the equipment is not working properly in any way. In this event, immediately depressurise the device by
pulling on the pressure relief valve (Fig. 4) and have it checked by a specialist workshop.
Before pulling on the pressure relief valve (2), the device must always be in an upright position.
Attention: Keep the device away from your face!
If you have any questions please refer to your authorised SOLO dealer.
Standard device with shut-off valve assembled on the high-pressure hose
Spray tube with assembled nozzle attachment
These operating instructions (incl. EC declaration of conformity)
ENGLISH 10
Check whether the device is safe to use:
Visual inspection of the device
Check the tightness of all equipment compo-
nents (at maximum permissible pressure with
open and closed shut-off valve)
Check the function of all active components
(pressure relief valve, shut-off valve, pump
handle, pressure gauge (depending on the
model))
Visual inspection
Visual inspection
Clean (section 5.5)
Clean (section 5.5)
Trial run to check the spray nozzles and the
filter element by measuring the delivery rate
(section 5.2)
X*: A monthly trial run is required only if the
device is used frequently.
Grease (section 5.4)

6 Standard delivery

X
X
X
X
X
X
X
X
X
X*
X
X
X