Changing The Vacuum Pump Oil - Waeco AirConService ASC5000RPA Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ASC5000RPA/ASC5500RPA
9.6

Changing the vacuum pump oil

!
WARNING!
Switch off the AirConServiceCenter and unplug it from the power
supply before opening the housing.
1. Before changing the oil, let the vacuum pump run for about 10 min-
utes (manually, via the menu).
The following steps may only be performed by qualified personnel.
2. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
3. Place a receptacle with a capacity of at least ½ litre under the
AirConServiceCenter. The oil from the vacuum pump flows through
the opening (I) in the base of the unit.
EN
D
E
H
I
D
E
G
J
Service tasks
115

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Airconservice asc5500rpa

Tabla de contenido