WARNING!
Do not cover the sauna heater. This creates a fire hazard.
Do not touch the top of the heater. This will cause severe burns.
Incorrect ventilation or an incorrectly placed sauna heater can,
under certain circumstances, cause excessive drying of the wood in
the sauna and create a fire hazard.
Cover sauna floors with a non-slip material.
Never hose down the sauna.
There must always be at least 50 mm (2.0 in) insulation directly
behind the wood panelling in the sauna (no other material may be
used, such as particle board, plaster, etc).
Sauna doors must always open outwards. All that should be needed
to open the sauna door is just a little light pressure.
Do not use the sauna for any purpose other than sauna bathing.
Do not install more than one sauna heater in a sauna room, unless
you follow exactly the special instructions for twin-heater
installations.
Sauna fragrances, etc. may ignite if poured undiluted into the stone
compartment.
Never leave young children unattended in the sauna.
Sauna bathing is not always suitable for persons in poor health.
Consult your doctor for advice.
Keep this information for future reference.
INSTALLATION
Fig. 1.
The Tylö Combi sauna heater (built-in control panel).
The Tylö Combi RC sauna heater (separate control panel CC 20,
which is delivered with the heater).
Installing the sauna heater.
The sauna heater should be placed on the same wall as the door, see
figure 7. As an exception, the heater may be placed on a side wall,
but as close as possible to the wall with the door. Fit the heater
270 mm (10.6 in) above the floor, observing the regulations for the
minimum distance to the side wall.
Tylö sauna heaters are connected by a standard cable approved for
permanent installation. The cable or conduit is laid on the outside of
any heating insulation; see fig. 4. A single-conductor cable should be
protected by a plastic conduit up to the heater, or in flexible metal
conduit with internal insulation.
When the heater has been installed, a set screw (K, fig. 4) locks it in
place so that the heater cannot be removed from the wall.
Fig. 2 – Minimum safety distances.
A = standard installation. B = recess installation.
Please refer to the table for minimum distances to side wall (X,Y).
When installing Combi RC model sauna heaters in a recess, the
sensor (C) should be placed 250 mm (9.8 in) from the rear wall of the
recess and 1500 mm (59 in) above floor level.
Fig. 3 – Minimum safety distances.
Minimum distance to sauna fittings in front of a sauna heater.
Fig. 4 – Combi/Combi RC.
A = electric conduit. B = wooden panel. C = insulation. D = built-in
sensor (Combi). E = sensor (Combi RC, should be installed on the
wall 1500 mm (59 in) above floor level). F = built-in control panel
(Combi). G = separate control panel (Combi RC). H = Hanging
console. I = vent. J = wooden batten. K = set screws.
L = temperature limit control (in the reservoir). M = drainage pipe.
Fix the hanging console at a minimum distance (N) of 180 mm
(7.1 in) from the side wall and 675 mm (26.6 in) above floor level (O).
6
All manuals and user guides at all-guides.com
Fig. 5 – Combi.
1 = sauna heater. 5 = mains fuse box.
Fig. 6 – Combi RC.
1 = sauna heater. 2 = thermistor (sensor). 3 = control panel CC 20.
4 = external on/off-switch (if any). 5 = mains fuse box.
Amperage and conductor area:
kW
6,6
Volume and minimum installation distances:
power
Installation of separate control panels.
(Combi RC only).
Control panel type CC 20 is electronically controlled, and can have
a remote control at one or more locations. The control cable between
the sauna heater and the control panel must be a shielded cable
(LiYCY). Connect the shielding to plinth 12 in the CC20, see the
wiring diagram.
Install outside the sauna room.
Fig. 16–17 Wiring diagrams.
1 = sauna heater. 2 = thermistor (sensor). 3 = control panel.
4 = external power switch (if any).
Check the heater's type identification plate to ensure the right voltage
before you connect the electricity supply. Don't forget to ground
the unit!
Unusual voltages or number of phases.
Before connecting the heater to a different voltage or number of
phases than those described in the wiring diagram, contact Tylö
Customer Service.
The importance of correct sauna ventilation.
Incorrect sauna ventilation can result in hot floors and benches,
scorched walls and ceilings (the temperature limit control will be
triggered)! So we do urge you to follow our instructions for sauna
ventilation carefully.
Adjust the air outlet to evacuate 6–8 cu.m (7.8-10.5 cu.yd) of air per
person, per hour, when the sauna is in operation.
Mechanical sauna ventilation is not to be recommended, as the
forced air supply can cause a fire hazard through the wooden
panelling drying out.
Fig. 7. Sauna heater and door on the same wall.
The "air circulation" created by the door should work together with
the hot air generated by the sauna heater. To facilitate this, the heater
should be placed on the same wall as the door (If exceptional
circumstances require the heater to be fitted to a side wall, make
sure it is located in close proximity to the wall with the door).
Fig. 8. Inlet vent always directly below the heater.
The inlet vent should be driven straight through the wall directly below
the centre of the sauna heater. The cross-section of the vent for a
family sauna is approx. 125 sq.cm (19.4 sq.in).
230-
230-
400- 415V
240V 3~
240V~
3N~
amp
mm²
amp
mm²
amp
17
4
29
10
10
8
20
4
35
10
12
Sauna
Min. distance from side wall
volume
kW
min/max
standard
cu.m.
installation
"X"
6.6
4–8
110
8
6–12
110
BUILDING INSTRUCTIONS
200-
200-
208V~
208V 3~
mm²
amp
mm²
amp
mm²
1,5
33
10
19
4
2,5
40
16
23
6
Minimum
ceiling
(mm)
height
recess
in sauna
installation
(mm)
"Y"
200
1900
200
1900