radio: Connected device with double push-buttons
for roller shutter
MVr500eBrP
5454812
Function
This module can be used to locally control shutters, blinds and motorised curtains by means of:
- buttons on the device;
- radio remote control.
It also allows radio centralisation (with code 5454816 or remote control) or wired (with code
5454818).
Compatibility
The MVR500EBRP module is compatible with all three-wire motors (common, opening,
closing). The limit switches may be either electric or electronic and set on the shutter itself.
If mechanical limit switches are used, the shutter travel is defined by mechanical stops. In
this case, the MVR500EBRP module will detect an overload and immediately cut off power
to the motor. The MVR500EBRP module is also compatible with four-wire motors (phase,
neutral, up, down) in permanent up and down control mode.
It is not compatible with tubular motors with integrated radio receiver.
technical specifications
3-wire motor power
Mains voltage
Ambient temperature
Relative humidity
Module consumption
Radio frequency band:
Maximum radio power transmitted:
Degree of protection
Dimensions of buttons (L x A)
Dimensions of module(L x A x P)
WIRING
Centralisation can be used to control multiple MVR500EBRP
devices with an additional radio control and the shutter
centralisation module code 5454816 or a remote control.
Centralised
RADIO control
Remote control
Optional
L
N
5454816
Optional
230V
50Hz
The module must be installed only by qualified personnel and into a place the end-user cannot access, according to the installing national rules.
In order to follow the safety rules, the module must be connected to a power line that is upstream protected by a magnetothermic switch 10A C
curve. Wire the module only when power is off. In three-phase installations the powering phase of the modules and of the driver wire should be
the same. Contact Customer Care for three-phase system wiring diagrams.
1. Connect the mains power between the 'L' and 'N' Terminals.
2. Connect the motor wires to the 'MN', UP' (opening), 'DW' (closing) terminals. Check that the 'UP' terminal is actually connected to
the opening wire. Do not rely on the colours of the motor wires. To check if the motor was connected correctly, carry out 3 short
presses on the pushbutton and ensure that the shutter opens. 4 short presses should cause the shutter to close. If the operation is
the opposite of the above, invert the connections of the two motor wires on the MVR500EBPRER module.
DS1054-065A
Connected device with double push-buttons for roller
shutter flush-mounted , 1 module
230V ~ 2A max. 500VA
230V ~ +10% -15% - 50Hz
-20°C +40°C
from 0 to 70%
< 1VA - < 0,3W
2400 - 2480 MHz
10mW
IP30
22,5 x 45 mm
22,5 x 50 x 46,8 mm
Shutter
E5
Centralised
WIRED control
E5
5454818
Optional
L
N
Centralisation can also be
achieved using a pilot and a
module code 5454818.
Shutter
R1
5454812
DRIVER WIRE
P8
GB
PoWer range (*):
• Inside 100 m² apartments
with perpendicular crossing
of main wall or ceiling
• 250 m in open range
(Note: in both cases the
range may be reduced by the
presence of metallic
elements, crossing of walls or
partitions)
radio traNSMiSSioN
the transmitter Led lights up
only if the radio transmission
was successful.
Adding an intermediate receiver
will solve the problem of
insufficient range.
Refer to the transmitter
instruction booklet for more
information.
Loghi
Structure with contact
opening microdistance
For radio centralisation, refer to the
instruction booklet of module code
5454816 or the instruction manual of
Specific
RADIO control
E5
Remote control
Optional
R1
5454812
Motor

Publicidad

loading