Problem
Engine fails to start
Loss of power, operation
erratic
Too much vibration
Unit does not discharge
Rate of discharge slows
considerably or composition
of discharged material
changes
Trouble shooting guide
Possible cause(s)
Empty of tank or stale fuel.
Spark plug wire disconnected.
Faulty spark plug.
When engine is cold:
Lever not in position "CHOKE"
Cannot pull recoil cord.
Spark plug wire loose
Unit running on CHOKE
Blocked fuel line or stale fuel
Water or dirt in fuel system.
Carburetor not adjusted.
Air filter dirty.
Loose parts or damaged impeller
Discharge chute clogged
Or
Foreign objects lodged in impeller /
flail screen
Vacuum bag is full
Chipper blade(optional) dull
Fill tank with clean, fresh fuel.
Connect wire to spark plug.
Clean, adjust gap or replace
Put lever in position "CHOKE"
Obstruction logged in impeller. Remove
logged object, see section MAINTENANCE
Connect and tighten spark plug wire.
Move lever to "RUN"
Clean fuel line; fill tank with clean, fresh
gasoline
Disconnect fuel line at carburetor to drain
fuel tank. Fill tank with clean, fresh gasoline
Have carburetor adjusted by authorized
service dealer
Clean air filter. See section
MAINTENANCE.
Stop engine immediately and disconnect
spark plug wire. Tighten all screws and nuts.
If the vibrations don´t stop, have unit
serviced by an authorized service dealer.
Stop engine immediately and disconnect
spark plug wire. Remove lodged objects.
See section MAINTANANCE
Empty vacuum bag
Have chipper blade sharpened or replaced
by an authorized service dealer
7