ENGLISH
Gas adjustments
Use pressure regulators that are suitable
for the gas pressure values indicated in the
injectors table.
If the appliance is arranged for a type
of gas different from that available, it is
necessary to change the injectors, adjust
the minimum flame, change the outlet
connector.
Carry out the following operations to
change the hob injectors: remove the grills;
remove the burners, the burner caps (see
Fig. 6); change the injector and replace it
with one suitable for the new type of gas
(see injectors table).
Fig. 6
Replace the gas calibration label with the
new label included in the injector bag.
Refit everything in reverse order, making
sure to correctly fit the burner cap on the
burner.
All manuals and user guides at all-guides.com
Minimum flame for hob taps
To adjust the minimum flame, proceed as
follows:
•
Turn the adjustment screw anticlockwise to
increase the flame, or clockwise to decrease
it. Adjustment is correct when the flame is
approx. 3 - 4 mm.
The adjustment screw must be completely
screwed down for butane/propane gas.
Make sure the flame does not go out when
switching suddenly from high to low flame
Refit the knob.
Gas appliances
This appliance is not connected to a fume
exhaust device.
Therefore it must be installed and connected
in compliance with current and local
installation regulations.
Particular attention must be paid to the
applicable standards concerning room
ventilation.
Light the burner and turn the knob to
minimum ; remove the tap knob. Insert
a small screwdriver next to the tap pin
(Fig. 7).
Fig. 7
and vice versa.
24