Installation Requirements; Electrical Requirements; Recommended Grounding Method - Hisense 12K BTU Instrucciones De Instalacion Y Uso

Ocultar thumbs Ver también para 12K BTU:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.

Recommended Grounding Method

This
air conditioner must be grounded. This air
conditioner is equipped with a power supply cord with a
three-prong grounding plug. The cord must be plugged
into a mating, grounded three-prong outlet, grounded in
accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's
responsibility to have a properly grounded three-prong
outlet installed by a qualified electrical installer.
It is the customer's responsibility:
To contact a qualified
electrical installer
To assure that the electrical installation is
adequate and conforms to the Nation Electrical
Code,ANSI/NFPA 70-last edition,and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
Nation Fire Protection Association
1 Batterymarch Park
Quincy,Ma 02169-7471
www.nfpa.org

INSTALLATION REQUIREMENTS

Electrical Requirements

.
Wiring requirement
Power supply
12K BTU cooling&heating
208/230V
18K BTU cooling only
187.2V min.
18K BTU cooling&heating
253 V m ax.
24K BTU cooling only
24K BTU cooling&heating
Power Supply Cord
A. Test button
B. Reset button
NOTE:
Your air conditioner's device may differ from the one shown.
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of a second.
T o test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The
power supply cord is ready for operation.
NOTE:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
3
Time-delay fuse
Model
(or circuit breaker)
18A
20A
A
15A
B

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido