UNIT CLAMP DOWN INFORMATION
Once unit is installed in counter
opening, you must clamp unit down
as shown.
To clamp down, insert bracket with
offset side of angle into slot on each
side of unit. The thumb screw
should then be run thru bracket and up against bottom
of counter. Tighten until unit draws down.
2
PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
FOR PROPER OPERATION, THE MAXIMUM INLET
PRESSURE TO THE REGULATOR MUST BE NO MORE
THAN 14" OF WATER COLUMN (W.C.) PRESSURE.
For checking the regulator, the inlet pressure must be at
least 1" (or .25 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
The gas supply line to the oven should be 1/2" or 3/4"
pipe.
LP/PROPANE GAS CONVERSION
This appliance can be used with "Natural Gas" and
"Propane Gas". It is shipped from the factory for use
with natural gas.
If you wish to convert your cooktop for use with propane
gas, use the supplied fixed orifices in the package
containing the Installation Instruction Manual, in a bag
marked "FOR LP/PROPANE GAS CONVERSION". Follow
the installations instructions packaged with the orifices.
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all codes and requirements of the
authority having jurisdiction. Failure to follow instructions
could result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for the conversion.
Failure to make the appropriate conver-
sion can result in personal injury and property damage.
IMPORTANT
Remove all packing material and literature from cooktop
before connecting gas and electrical supply to cooktop.
3
1. Install the pressure regulator with the arrow on the
regulator pointing up toward unit and in a position
where you can reach the access cap.
!
Do Not make connection too tight. The regulator is
die cast.
Overtightening may crack regulator resulting in a gas
leak and possible fire or explosion.
1/2" nipple
manual
shutoff valve
All connections must be wrench-tightened.
2. Assemble the flexible connector from the gas suply
pipe to the pressure regulator in order: manual
shutoff valve, 1/2" nipple, 1/2" adapter, flexible
connector, 1/2" adapter, and 1/2" nipple.
3. Use pipe-joint compound made for use with
NATURAL and L.P. gas to seal all gas connections.
If flexible connectors are used, be certain connectors
are not kinked.
4. The supply line shall be equipped with an approved
shutoff valve. This valve should be located in the
same room as the cooktop and should be in a
location that allows ease of opening and closing.
Do not block access to shutoff valve. The valve is for
turning on or shutting off gas to the appliance.
to range
Open the shutoff valve in the gas supply line. Wait a
few minutes for gas to move through the gas line.
!
Do Not use an open flame to test for leaks from gas
connections.
Checking for leaks with a flame may result in a fire or
explosion.
ENGLISH – 5
W A R N I N G
Fire Hazard
flexible connector
1/2" nipple
1/2" adapters
pressure
regulator
shutoff valve
W A R N I N G
Fire Hazard
to gas
supply line