1.
Power input
2.
Phase sequence relay
3.
Vacuum cleaner
1.
Transformer
2.
Voltage indicator
3.
White lamp
1.
Stop button
2.
Start button
3.
Motor drive contactor
4.
Phase sequence indication
5.
Max level indicator
6.
Capacity Sensor
7.
Yellow lamp
8.
Power input
9.
Relay
1.
Fuse box
2.
Cartridge kit
3.
Level check
Item
Type
AL1
Z58 39783
H1
40000563
H3
40000564
H4
40000564
Z8 39211
K1
Z8 39118
KM1
4083901550 Contactor kW4 24VAC 1NO
PA
40000565
PM
40000562
4083901538 5.5-8 A circuit breaker
Q1
4083901540 9-12.5 A circuit breaker
SF1
Z8 391120
TR1
Z8 391050
GB
C380
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Description
Rectifier stabilized 3A
White indicator kit
Yellow indicator kit
Yellow indicator kit
Relay 24
VDC 2 changes
Stop button kit (red)
Start button kit (green)
Phase sequence relay 400 V
Transformer 20 VA 400/24 V
Additional information about special
versions "Asbestos"
Asbestos vacuum cleaners (in accordance with German
specification TRGS 519)
Vacuum cleaner models designed for asbestos are:
T40WPLUS H AA.
1. After the asbestos vacuum cleaner has been used in
contaminated zones as established by TRGS 519, it
cannot be used in a healthy environment. Exceptions
are permitted if the asbestos vacuum cleaner has
been completely decontaminated (not just the outer
casing but also the air cooling zone, the casings
where the electric components are assembled
(electric panels), the electric components themselves,
etc.), by qualified personnel in compliance with TRGS
519 N. 2.7.
This activity must be reported and recorded in writing
by qualified personnel.
2. The filters must be replaced in suitable places (e.g. a
decontamination station) by qualified personnel.
Q.ty
3. The filter must only be replaced by qualified
1
personnel in accordance with the instructions given in
1
this manual.
1
4. When the asbestos vacuum cleaner is being handled
1
and transported, always close the inlet with the
relevant plug. If the vacuum cleaner is transported
1
outside the contaminated zone, it must be cleaned as
1
described in point 1.
1
Alternatively, the asbestos vacuum cleaner must be
carefully closed in a sealed hermetic bag.
1
This activity must be reported and recorded in writing
1
by qualified personnel.
1
5. Fitting the drain hose: insert the hose into the air
1
outlet on the special panel supplied. Fully tighten the
1
supplied screw clamp making sure that the hose is
unable to slip off.
6. Only qualified personnel may dispose of the
container.
Also refer to the "Maintenance, cleaning and
decontamination" paragraph of this manual for more
details about points 2, 3, 4, 6.
14
WARNING!
[ NOTE ]
03/2017

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T40plusT40w plus

Tabla de contenido