INSTALLATION INSTRuCTIONS
6. Connect the Supply Adapter
CAUTION
Do not bend or kink tube when inserting.
NOTE: Ensure that all tubing ends are fully pushed past the o-rings on
the system inlet/outlet and inlet adapter fittings.
A)
Determine the length of plastic tubing needed to connect the inlet
(left) side of the filter with the inlet supply adapter installed on the
cold water supply line. Be sure to allow enough tubing to prevent
kinking and cut the tubing squarely. Place a mark 5/8 inch from
one end of the tubing. Wet the end of the tubing. Insert the end
of the tubing into the 1/4-inch fitting of the inlet supply adapter.
The 5/8-inch mark should be flush with the white collar of the
fitting located on the inlet supply adapter.
B)
Use a marker to mark 5/8 inch from remaining end of the tubing.
Wet the end of the tube. Insert the end into the white collar fitting
on the inlet side (left) of the system. The tube should go in up to
the mark.
7. Install the Filter Cartridge
NOTE: The 1500R Cartridge must be installed on the left side. The
1750R Cartridge must be installed on the right side.
NOTE: The system is designed to ensure proper alignment of the
cartridge to the filter head assembly prior to installation.
A)
Align the tab on the filter cartridge with the slot in the filter head
assembly (Figure 7A).
B)
Place hand on filter head assembly to steady the system. Slide the
cartridge filter up into the head assembly until it can go no further.
Rotate the cartridge clockwise 1/4 turn until the cartridge can go
no further (Figure 7B).
8. Place the System into Operation
A)
Slowly turn on the cold water supply.
B)
Flush filter for 5 minutes through the faucet and discard water.
C)
Check for leaks at all fittings before leaving installation. If leaks
appear, see troubleshooting.
NOTE: A drinking water cartridge may contain carbon fines (very fine
black powder). If carbon fines appear in the water, discard water.
More flushing is required if carbon fines are present.
NOTE: Initially, filtered water may appear cloudy. If cloudiness in
a glass of water disappears from the bottom, fine air bubbles are
present. This air within the water will disappear within a few weeks
after installation.
INSTALLATION IS NOW COMPLETE.
Continued
5E
Vertical
installation
When mounting
system vertically,
bracket must
straddle the
center of the
system and slide
into BOTH slots.
5B
5C
5/8"
6B
NOTE: When
replacing any
tubing, cut
tubing back 1/4
inch prior to
re-inserting to
prevent leaks.
6A
7B
7A
Slot
Tab
Drip
loop
5/8"
5/8"
1750R
A
1500R
B