˚ English
We are delighted that you have purchased one of our products.
These are usage instructions to help you familiarise yourself with your new purchase. All the documents accompanying the product must be read
attentively before using the product, preserved carefully and if the product is transferred to a third party, the documents must be handed over as
well. This ensures that maximum benefit is drawn from the product and questions from users are anticipated before they arise.
Above all, comply with the warnings and safety instructions and dispose of the packaging material properly.
Under point 12 and 13 it is explained how the lamp head is separated from the Power Module and how the rear part of the shaft of the lamp is
unscrewed. Both actions described under point 13 and 14 must be carried out before initial use of the lamp; they are necessary in order to remove
and dispose of the two insulating films (one on each side). These two films serve as protection during transport of the "Safety Ytrion Cell" battery
pack.
After taking off the insulating films, you must screw the rear part to the middle part first before pushing the switch button; otherwise the lamp might
not work properly. Now, you can screw the Power Module (rear part plus middle part) to the lamp head.
Product
LED LENSER
8417-R Led Lenser P17R
Version of the operating manual: 1.1
1. Battery set:
1 × Power Module (shaft including "Safety Ytrion Cell" battery pack); no other batteries or accumulators are permitted
2. Switching on and off
In the front section of the P17R, directly behind the wide head, the switch button is located. This switch button can be used to select different Light
Functions (see Point 6).
What is important here is that there are 2 ways of actuating the switch button:
a) Switching
The switch button is pressed beyond the pressure point, i.e. so deep that the switch clicks into place. A small sound, a click, can be heard.
b) Tapping
The switch button is only tapped briefly and not as deeply as in a) above. As a result, the switch does not click into place, there is no click
audible and the switch remains in the starting position when it is released.
To switch on the P17R use the switch button as described under a. In order to use the Light Functions please read Point 6 "Light Functions".
The descriptions above apply to the switch button directly behind the wide head.
Please do not confuse it with the switch button (see Point 9), which is formed by the two concentric charging contacts at the end of the torch.
3. Focus
The focus of the P17R can be quickly adjusted with the help of the so-called Speed Focus. For this purpose, hold the torch on the serrated middle
section firmly with one hand and with the other hand, push the wider lamp head in which the reflector lens is located, to the front or to the back. By
doing this, you can adjust the light beam continuously variably to suit your needs.
4. Fast Lock
If required, a desired focus setting can be locked by means of the so-called Fast Lock. What this does is to prevent the focus setting from getting
accidentally changed. To do so, the lamp head must be turned left with respect to the shaft, i.e. in the direction of the legend "Lock" on the lamp
head. To release this fixed setting and to once again allow the continuously variable setting of the focus (see Point 3), the lamp head has to be
turned in the other direction, i.e. the direction of the legend "Unlock".
5. Smart Light Technology (SLT)
The P17R is equipped with our Smart Light Technology (SLT). Thanks to the use of a microcontroller, the light output of the LED can be controlled
and the user can use different Light Functions. By using a single switch it was possible to design the interface to be simple and user-friendly. The
pocket torch can give the user light in different ways. There are three Light Functions available. To switch the pocket torch on and off and to select
the various Light Functions, the switch in its front section has to be used. Here, the switch is used in the two ways described above in Point 2.
What basically applies is that the brightness of the P17R is monitored by the in-built temperature control unit.
6. Light Functions
The 3 Light Functions are chosen at the switch button as follows:
6.1. Light Program Power
The P17R is turned on by switching 1 time. Then you have full brightness (Power). One more switching operation and the lamp is off.
6.2 Light Program Low Power
If you tap the switch button on the lamp head 1 time and switch then within one second the P17R will have reduced brightness (Low Power).
Another possibility to have the reduced brightness is to switch 3 times fast.
6.3 Light Program Strobe
If you tap the switch button on the lamp head 2 times and switch then within one second the P17R is in the Light Function Strobe and flashes
quickly (Strobe).
Another possibility to activate Light Function Strobe is to switch 5 times fast.
7. Emergency Mode / Emergency Light Function
When the Emergency Mode is activated, the P17R has an emergency light function. For this purpose, the mode has to be activated and the P17R
has to be connected to the charger (position light at the charger glows blue, see Point 9). In this case, the pocket torch automatically goes on
when the electric supply that is providing energy to the charger fails. If positioned meaningfully, the P17R, when it is glowing, can facilitate quickly
finding an escape route in an emergency, or the lamp can be quickly found and picked up, already on. If this function is active, the P17R glows
automatically even if the charging process is interrupted by removing the P17R. Therefore, the function can also be used when the P17R has to be
ready for immediate use.
To set the "Emergency Mode", tap the switch button 6 times, followed by a switching operation. The P17R glows in the Light Function "Power"
for a moment, first it blinks 2 or 4 times, then the light turns off. When it blinks 4 times, the "Emergency Mode" is activated; if it flashes twice, the
"Emergency Mode" is disabled. If this procedure is carried out again, the setting toggles between activated and disable- it signals this by blinking.
No matter if the "Emergency Mode" setting is activated or disabled, after the light turns off, the switch is still in the "on" setting. In order to take the
next step, the lamp has to be switched off first.
8. Reset function
If the Power Module (shaft with "Safety Ytrion Cell" battery pack) is unscrewed completely at the head and the two parts are screwed together again
only after a little while, you have "reset" the P17R. You have an activated Emergency Mode (see Point 7) then.
9. Charging
The Power Module (shaft without lamp head) contains the "Safety Ytrion Cell" battery pack, the accumulator.
03