Descargar Imprimir esta página

Mitsubishi Electric Mr. SLIM MSZ-FA25VA Technical Manual página 325

Ocultar thumbs Ver también para Mr. SLIM MSZ-FA25VA:

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Failure mode recall function
As this air conditioner has a function to memorize all the failures that had happened, the latest failure detail can be
recalled by following the procedures below.
Use this function when the check code is not displayed with wired remote controller or the remote controller at use is
wireless type.
2-1. Flow chart of the indoor/outdoor unit failure mode recall function
Operational procedure(For wireless remote controller)
Setting up the failure mode recall function
Turn ON the power supply.
1 While pressing both OPERATION SELECT button and TOO COOL
button on the remote controller at the same time, press RESET button.
2 First, release RESET button.
And release the other two buttons since all LCD in operation display
section of the remote controller is displayed after 3 seconds.
1
Press OPERATE/STOP (ON/OFF) button of the remote controller (the set temperature
is displayed)..
Does OPERATION INDICATOR lamp on the indoor
unit blink at the interval of 0.5 seconds?
Blinks: Either indoor or outdoor unit is abnormal.
Beep sounds are emitted at the same timing of the
blinking of OPERATION INDICATOR lamp.
Judgment of indoor/outdoor abnormality
Before blinking, does POWER
lamp stay ON for 3 seconds?
Stays ON for 3 seconds (without beep):
The indoor unit is abnormal.
Check the blinking pattern, and refer to confirm the
abnormal point.
Make sure to check at least two consecutive blinking cycles.
Releasing the failure mode recall function
Release the failure mode recall function by the following procedures.
1 With the remote controller headed towards the indoor unit, press any button
that is not used in this failure mode recall function (e.g. TIMER button) .
OR
1 Turn OFF the power supply and turn ON it again.
2 Press RESET button of the remote controller.
Note1.Make sure to release the failure mode recall function once it's set up, otherwise the unit cannot operate properly.
2.If the abnormal condition is not deleted from the memory, the last abnormal condition is kept memorized.
2. Blinking pattern when the indoor unit is abnormal:[Output pattern A]
Beeper sounds
Beep
OPERATION
INDICATOR
lamp flash
pattern
Approx. 2.5 sec.
Self-check
starts
(Start signal
received)
3.Blinking pattern when the outdoor unit is abnormal:[Output pattern B]
Beeper sounds
Beep
OPERATION
INDICATOR
lamp flash
pattern
Approx. 2.5 sec.
Self-check
starts
(Start signal
received)
2
Yes
(Blinks)
The outdoor unit is abnormal.
No
Repair the defective parts.
Beep
Beep
Beep
1
st
2
nd
3
rd
Off
On
On
On
0.5 sec.
0.5 sec.
0.5 sec.
0.5 sec.
Number of flashes/beeps in pattern indicates the check
code in the next page (i.e., n=5 for "P5")
Beep
st
1
Off
On
On
Approx. 3 sec.
0.5 sec.
Number of flashes/beeps in pattern indicates the check
code in the next page (i.e., n=5 for "U2")
ON/OFF
No
Indoor unit is normal.
(OFF)
There is a possibility that the plasma or outdoor unit is abnormal.
Confirm the failure detail on the LED display of the outdoor controller
board.(refer to 12-2-4.)
Yes
The outdoor unit is abnormal.
Check the blinking pattern, and refer to confirm the abnormal
point(12-2.3.).
2
Make sure to check at least two consecutive blinking cycles.
Beep
Beep
Beep
n
th
1
st
2
nd
· · · Repeated
Off
On
On
On
Approx. 2.5 sec.
0.5 sec.
0.5 sec.
Number of flashes/beeps in pattern indicates
the check code in the next page
Beep
Beep
Beep
nd
rd
th
2
3
n
On
On
On
Off
0.5 sec.
0.5 sec.
0.5 sec.
Approx. 2.5 sec.
Resolución de averías
1 While pressing both OPERATION SELECT
button and TOO COOL button on the
remote controller at the same time,
press RESET button.
2 First, release RESET button.
And release the other two buttons since all LCD
in operation display section of the remote controller
is displayed after 3 seconds.
h
TOO
TOO
WARM
COOL
1. Regardless of normal or abnormal, a short
beep is emitted once as the signal is received.
OPERATION INDICATOR lamp
Beep
Beep
st
nd
1
2
· · · Repeated
On
On
On
Approx. 3 sec.
0.5 sec.
0.5 sec.
Number of flashes/beeps in pattern indicates
the check code in the next page
3
325

Publicidad

loading

Este manual también es adecuado para:

Mr. slim msz-fa35vaMr. slim muz-fa25vaMr. slim muz-fa35vaMr. slim msz-ga22vaMr. slim msz-ga25vaMr. slim msz-ga35va ... Mostrar todo