PCA-RP50GA
PCA-RP60GA
PCA-RP100GA PCA-RP125GA PCA-RP140GA
SYMBOL
NAME
P.B
INDOOR POWER BOARD
I.B
INDOOR CONTROLLER BOARD
FUSE FUSE (T6.3AL250V)
ZNR
VARISTOR
CN2L CONNECTOR(LOSSNAY)
CN32 CONNECTOR(REMOTE SWITCH)
CN41 CONNECTOR(HA TERMINAL-A)
CN51 CONNECTOR(CENTRALLY CONTROL)
SWITCH (MODEL SELECTION) WSee Table 1.
SW1
SWITCH (CAPACITY CODE) WSee Table 2.
SW2
SWE SWITCH(EMERGENCY OPERATION)
X1
RELAY(DRAIN PUMP)
X4
RELAY(FAN MOTOR)
BCR
FAN CONTROL ELEMENT
LED1 POWER SUPPLY(I.B)
LED2
POWER SUPPLY(R.B)
LED3
TRANSMISSION(INDOOR-OUTDOOR)
C
CAPACITOR(FAN MOTOR)
P.B
MF
1 2 3
(OPTION)
C
DP
I.B
D.U.M
POWER
1 3
5
1 3
FAN
CNP
CNDK
( WHT )
(BLU)
(RED)
X4
BCR
X1
X4
X1
LED3 LED2 LED1
SW2
SW1
SWE
ON
OFF
Refer to tables 1
and 2 for service PCB.
WWhen installing optional
drain-up machine disconnect
the CN31 jumper connector
and replace it with the
CN31
drain sensor (DS).
DRAIN SENSOR
( WHT )
1 2 3
When installing drain-up
machine (Optional part).
DS
PCH-P50~P140GAH
models only
H1
FS1
1. When work to supply power separately to
Indoor and Outdoor unit was applied, refer to Fig 1.
2. For power supply system of this unit,
refer to the caution label located near this diagram.
Table 2
Table 1
MODELS
SW1
Service board
MODELS
PCA-RP50GA
PCH-P50GAH
1 2 3 4 5
PCA-RP.GA
ON
PCH-P.GAH
OFF
PCA-RP60GA
PCH-P60GAH
PCA-RP71GA
PCH-P71GAH
PCA-RP71GA
SYMBOL
MF
FAN MOTOR
MV
VANE MOTOR
DP
DRAIN-UP MACHINE (OPTION)
DS
DRAIN SENSOR (OPTION)
TERMINAL BLOCK (HEATER) WPCH-P.GAH
TB2
models only or option for PCA RP.GA models.
TB4
TERMINAL BLOCK(INDOOR/OUTDOOR CONNECTING LINE)
TB5,TB6
TERMINAL BLOCK(REMOTE CONTROLLER
TRANSMISSION LINE )
TH1
ROOM TEMP.THERMISTOR
(0; /15k , 25; /5.4k DETECT)
TH2
PIPE TEMP.THERMISTOR/LIQUID
(0; /15k , 25; /5.4k DETECT)
TH5
COND./EVA.TEMP.THERMISTOR
(0; /15k , 25; /5.4k DETECT)
R.B
WIRED REMOTE CONTROLLER BOARD
CNDK
CN2S
(RED)
(WHT)
1
1
2
2
DC13.1V
3
POWER
1 3
1 3
1 2
1 3
CND
INDOOR/OUTDOOR
(ORN)
POWER
COMMUNICATION
CN2D(WHT)
CN3C(BLU)
CN41
CN2L
ZNR
CN51
CN32
D.SENSOR
INTAKE
LIQUID
PIPE
REMOCON
CN31
CN20
CN21
CN29
CN22
( WHT )
( RED )
( WHT )
( BLK )
( BLU )
1 2 3
1 2
1 2
1 2
1 2
1 2
1 2
TH1
TH2
TH5
[Servicing]
Fasten terminal of the terminal board "TB4"equips lock system.
To remove the fastened terminal, pull it while pressing the protruding
portion (locking lever) of the terminal. The fastened terminal protruding
portion should face upward.
88H
TB2
FS2
L
RED
RED 5
3
RED
1
N
WHT
BLU
2
GRN/YLW
HEATER
CN24
1
2
(YLW)
I.B
6
88H
SW2
Service board
Service board
MODELS
1 2 3 4 5
1 2 3 4 5
PCA-RP100GA
ON
PCH-P100GAH
OFF
1 2 3 4 5
1 2 3 4 5
PCA-RP125GA
ON
PCH-P125GAH
OFF
1 2 3 4 5
1 2 3 4 5
PCA-RP140GA
ON
PCH-P140GAH
OFF
NAME
SYMBOL
W.B
RU
BZ
LED1
LED2
SW1
SW2
HEATER
FS1,2
H1
26H
88H
YLW
ORN
ORN
BRN
50~71 TYPE
VANE
6
6
6
6
CN6V
( GRN )
MV
100~140 TYPE
5
5
WIRELESS
CN90
9
( WHT )
CNB
BZ
RU
RECEIVER
LED1 LED2 SW2 SW1
W.B
2
1
TRANSMISSION WIRES DC12V
TB5
R.B
W 1 (Fig.1)
POWER SUPPLY
~(1PHASE)
230V 50Hz
I.B
1
26H
POWER
RED
6
CND
1
GRY
RED
5
(ORN)
NOTES:
1. Since the outdoor side electric wiring may change be sure to
check the outdoor unit electric wiring for servicing.
2. Indoor and outdoor connecting wires are made with polarities, make
ON
OFF
wiring matching terminal numbers (S1, S2, S3).
3. Make sure that the main power supply of the booster heater is
independent.
ON
OFF
4. Symbols used in wiring diagram above are,
: Connector,
ON
OFF
Esquemas eléctricos
NAME
WIRELESS REMOTE CONTROLLER BOARD(OPTION)
RECEIVING UNIT
BUZZER
LED(RUN INDICATOR)
LED(HOT ADJUST)
SWITCH(HEATING ON/OFF)
SWITCH(COOLING ON/OFF)
THERMAL FUSE(98; 10A:50GAH/117; 16A:100GAH
110; 16A:60,71,125,140GAH)
HEATER
HEATER THERMAL SWITCH
HEATER CONTACTOR
TB4
S1
S2
TO OUTDOOR UNIT
S3
MV
MV
Please set the voltage using the remote
controller.
For the setting method, please refer to
the indoor unit Installation Manual.
1 2
TB6
TB2
L
RED
POWER SUPPLY
BLU
N
~(1PHASE)
GRN/YLW
230V 50Hz
TB4
YLW
S1
ORN
S2
ORN
TO OUTDOOR UNIT
BRN
S3
3
1
3
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
: Terminal (block).
653