BAV MA-OD-00027-01
Smart Reordering System
4
Product description (continued)
4.1.2

Measurement and transmission intervals

By default, the sensor measures the distance to the
nearest object within the detection range every 2 minutes
and transmits the data to the gateway every 10 minutes.
The transmission frequency can be set to between
4 minutes and 24 hours and any change directly affects
the battery life (see Tab. 4-1). The battery life specifications
are theoretical, as the ambient conditions of the area of
use can also have an influence on the battery life.
360
4
2
240
6
2
144
10
2
48
30
6
24
60
12
12
120
24
6
240
48
1
1440
288
1)
SF (Spreading Factor) is a measure of the transmission speed. The higher
the SF, the longer the transmission time. The transmission time has a
significant influence on the battery life. The longer the transmission time,
the shorter the battery life. With increasingly poor connection quality
between gateway and sensor, the transmission speed reduces from SF7
downwards to SF12. Among other factors, the connection quality
reduces with increasing distance, physical barriers in buildings, machines
and steel structures between gateway and sensor.
To improve the connection quality, the gateway can be placed closer to
the sensor or another gateway can be used in closer proximity to the
sensor.
Tab. 4-1:
Influences on battery life
8
english
2
6
0.75
3
8
1
5
10
2
5
12
5
5
14
9
5
16
10
5
18
12
5
20
14
4.2

Operating and display elements

4.2.1

Button

Function
Operation
Activate sensor
Press the button briefly.
from shipping
mode.
Set sensor to
Press and hold the button until the
shipping mode.
yellow and red LEDs light up
simultaneously.
Reset sensor
Press the button until the yellow
(Reset).
and red LEDs flash.
Tab. 4-2:
Button operation
4.2.2

LEDs

LED
Cause – Sensor behavior
Red LED flashes
Internal Error – Sensor goes into
quickly ten times.
shipping mode.
Red LED flashes
Measurement failed – Sensor goes
slowly five times
into shipping mode.
and then lights up
for five seconds.
Yellow and red
LoRa Join failed – Sensor tries to
LEDs flash slowly
reconnect to the gateway first
three times
every 4 minutes and then every
simultaneously.
hour.
45.6
Yellow LED lights
A distance measurement is
up for two
performed with subsequent data
seconds.
transmission via LoRaWAN.
Yellow LED flashes
Data was successfully transmitted.
three times.
Tab. 4-3:
LED indicators
4.3

Labeling

1)
2)
Order code
1)
Type
2)
Fig. 4-3:
Labeling (example)
Ø 3.5
5
22.5