1. About the Machine / Technical Data _________________
Dimensions and Performance Data
External dimension device:
Length:
Width:
Height:
Working Area (inside dimension):
Working height:
Weight without drum:
Weight with drum (full)
Bearing capacity:
Fill volume:
Noise emission value
at work station:
Electrical Connection
Power supply:
Frequency:
Power draw:
Max. back-up fuse
Pneumatic Conntection (Option)
Pressure:
Pressure connection:
2. Proper and Appropriate Use __________________________
The Parts Cleaner Types Typ F and F2 have been designed for cleaning oily and greasy metal parts
(e.g. machine parts, motors and housings) using Special Cleaners.
2.1. Approved Solvents
Solvents used with this machine must not contain halogenated hydrocarbons and must meet
the following requirements:
• Flash point > 55°,
• No danger labels in accordance with the German Hazardous Materials Act, except for
materials labelled only as Xn in connection with R 65 (Harmful: may cause lung damage if
swallowed).
NOTICE
The extended 3-year warranty covering device and pump applies only if IBS Special
Cleaners are used. Before using solvents by other manufacturers you must check
the corresponding EC Material Safety Data Sheet and take advice from the
producer before using them!
2.2. Non-Approved Solvents
The use of highly inflammable and inflammable liquids inside this machine is prohibited.
The introduction of liquids with a flash point < 55°C, such as motor gasoline, is
prohibited.
DANGER
Please observe any relevant local and national legal requirements concerning the use of solvents for
parts cleaning.
Operating Instructions Parts Cleaner Type F/F2 (02/2010/EN)
Type F
570 mm
555 mm
1145 mm
560 x 430 mm
920 mm
27 kg
77 kg
40 kg
50 l
< 70 dB (A)
1/N/PE 230 V ~
50 Hz
45 W – 0,2 A
6 A
max. 4 bar
1/8"
Type F2
800 mm
615 mm
1120 mm
790 x 490 mm
920 mm
43 kg
93 kg
100 kg
50 l
< 70 dB (A)
1/N/PE 230 V ~
50 Hz
45 W – 0,2 A
6 A
max. 4 bar
1/8"
3
Page