Level Switch
Level switch is used to tell if the level of coolant in the tank drops below certain level. When the level of the cool-
ant drops below level switch position in the tank, control board reads the switch open signal, an error signal is
PROPRIETARY AND CONFIDENTIAL
sent to CNC/Process controller by the Plasma Console through CAN communication.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY
OF ESAB WELDING & CUTTING. ANY REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN PERMISSION OF ESAB WELDING & CUTTING
IS PROHIBITED.
VENDOR:
VENDOR P/N:
Coolant Filter
A filter is used to prevent the foreign particles entering the Plasma Console through coolant and damaging the
equipment.