10 flashes - short pause
Error in movement time-out
10 flashes - long pause
Note - The diagnostic signals provided by flashing leds stop when the control unit is given a command.
By using an external flashing light*, the diagnostics signals continue for two sequences of flashes (e.g. "3 flashes – short pause – 3 flashes – long
pause" repeated twice).
IMPORTANT: To connect the external flashing light, you need to use the additional NDA040 board (not supplied).
* Configured with the Oview programmer as "Flashing Light 1".
Signal
Flashes fast alternating red LED and green LED
4 flashes - pause - 4 flashes of the LED simultaneously
Signal
On
Off
7
WHAT TO DO IF...
The following is a list of possible malfunctions that may occur during installation or due to a failure, together with the possible solutions:
• The motor is at a standstill, no manoeuvre is commanded and the red LED flashes: verify the type of flashing by checking the L1 LED Diagnostics
table (Section 6.2) and press the red STOP button to cancel the diagnostics.
• The radio transmitter does not control movements and the LED on the transmitter does not come ON: check to see if the transmitter batteries
have run down and replace them, if necessary.
• The radio transmitter does not control movements but the LED on the transmitter comes ON: check to see if the transmitter is correctly saved
on the radio receiver. Also, check that the transmitter sends its radio signals correctly, by performing the following empirical test: press any button on the
transmitter and place its LED on the aerial of any ordinary radio that is ON and tuned to 108.5 Mhz (or close to it) on the FM band; in this way, you should
hear a slight noise with crackling pulses.
• When a command is sent, no manoeuvre takes place and the OK LED does not flash: check that the control unit is connected to mains supply
with voltage of 230/400V. Also, check that the fuses have not blown; if they have, identify the cause of the failure and then replace them with others of the
same type.
• When a command is sent, no manoeuvre takes place and the flashing light is OFF: check that the command is actually received; if the command
reaches the SS input, the OK LED flashes twice to indicate that the command has been received.
• The manoeuvre fails to start and the flashing light flashes a few times: count the number of flashes and check the meaning of the flashes with the
diagnostics table in paragraph 6.2
• The motor turns in the opposite direction:
- for a three-phase motor, you need to invert the "V" and "W" phases of the motor
- for a single-phase motor, you need to invert the "V" and "W" phases of the motor
• The manoeuvre starts but stops shortly after: identify the cause using the diagnostics of the Leds on the control unit.
• The red WARNING L1 led flashes 9 times followed by a pause: there was an error in the recognition procedure of the Opening and Closing positions.
You must delete the memory (see 3.9) and repeat the position recognition procedure (see 3.10).
8

DISPOSAL OF THE PRODUCT

This product is an integral part of the automation system, therefore it must be disposed of along with it.
As in installation, also at the end of product lifetime, the disassembly and scrapping operations must be performed by qualified personnel.
This product is made up of different types of material, some of which can be recycled while others must be disposed of. Seek information on the recycling and
disposal systems envisaged by the local regulations in your area for this product category.
Caution! – Some parts of the product may contain pollutants or hazardous substances which, if released into the environment, may cause serious damage to
the environment or human health.
As indicated by the symbol on the left, disposal of this product in domestic waste is strictly prohibited. Separate the waste into categories for
disposal, according to the methods envisaged by current legislation in your area, or return the product to the retailer when purchasing a new
version.
Caution! – Local legislation may envisage serious fines in the event of abusive disposal of this product.
All manuals and user guides at all-guides.com
The default setting for the movement time-out is 60 seconds. Check
whether there are any obstructions to the movement of the gate
or whether the gate has actually performed the movement. Check
whether the duration of the timer has been changed (using the
Oview programmer if available). Repeat the recognition of the Open-
ing and Closing positions.
L1 and L2 LED DIAGNOSTICS
SAFETY LED DIAGNOSTICS
Cause
Correct operation
Safety chain open
(troubleshooting guide)
Cause
Firmware updating phase in progress
Awaiting firmware updating
Solution
---
The safety chain is made up of the series of inputs (ALT, Stop via button, motor
thermal protection, motor release). Close the circuit
---
English – 9