9
TECHNICAL SPECIFICATIONS
WARNINGS: • All technical specifications stated herein refer to an ambient temperature of 20° C (± 5° C). • Nice S.p.A. reserves the right to apply modifications
to products at any time when deemed necessary, maintaining the same intended use and functionality.
Type
Power supply
Motor max power
Power in Standby
Fuse on power board
Output 1 (with NDA040)
Output 2 (with NDA040)
Services output
"STOP SAFETY EDGE" Input
"ALT" Input
(OPEN) input
(CLOSE) input
ING1 (photo) Input
Radio connector
Radio AERIAL Output
Programmable functions
Auto-recognition functions
Operating temperature
Protection class
Vibration
Dimensions
Weight
10 – English
All manuals and user guides at all-guides.com
Control unit for single-phase or three-phase motors with Nice mechanical or electronic limit switches
Three-phase
3~400V AC / 3~230V AC (+10% - 10%) 50/60Hz
F1: 500 mA Type F; F2, F3, F4: 6.3A Type T
Voltage free contact (relay), programmable with Oview
Voltage free contact (relay), programmable with Oview
24 V DC (max 100 mA) between input 1 (com) terminal and gnd (-) STOP 8K2/OSE terminal (see Fig. 5)
For contacts that are normally closed, normally open or of the 8.2k Ω constant resistance type or the OSE
optical type; in auto-recognition (a variation from the memorised status causes a "STOP" command)
For Normally-Closed (NC) contacts on the safety circuit
For Normally-Closed (NC) contacts, programmable with Oview
SM connector for SMXI, SMXIS, OXI or OXIT receivers
52 ohm for RG58 or similar cables (maximum 10 m)
Functions programmable via the Oview Programming and Control Unit
Auto-recognition of the "STOP" type of device (OSE or 8.2KΩ resistance)
Installation free from movement, (e.g. on a brickwork wall)
1~230V AC (+10% - 10%) 50/60Hz
2.2kW
< 5W
For Normally Open (NO) contacts
For Normally Open (NO) contacts
-20°C ... +50°C
IP55
310 x 210 x 160 mm
2.5 kg
Single-phase