Connection To The Electrical Network - Svan SVTE501H Instrucciones De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.
The safety valve and the pipe between the valve and the water heater must be protected from freezing.
During hose draining - its free end must be always open to the atmosphere (not to be immersed). Make sure
that the hose is also protected from freezing.
4.
In order to secure the water heater's safe operation, the safety return-valve must undergo regular cleaning
and inspections for normal functioning /the valve must not be obstructed/, and for the regions with highly
calcareous water it must be cleaned from the accumulated lime scale. This service is not provided under
warranty maintenance.
5.
In order to prevent injury to user and third persons in the event of faults in the system for providing
hot water, the appliance must be mounted in premises outfitted with floor hydro insulation and plumbing
drainage. Don't place objects, which are not waterproof under the appliance under any circumstances. In the
event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with a
plumbing drainage must be placed under the appliance.
6.
During operation – regime of heating the water – water drops through the drainage opening of the protection
valve are usual. The protection valve should be left open to the atmosphere. Measures should be taken to lead
and collect the leakages in order to prevent damages.
7.
If the probability exists for the premise's temperature to fall below 0°С, the water heater must be drained.
In the event you must empty the water heater, first you must cut off its power supply. The inflow of water from
the water mains must first be terminated and the hot water tap of the mixing-faucet must be opened. The
water tap 7 (fig 4) must be opened to drain the water from water tank. If there is no such tap build in the pipe
line, than the water can be drain directly from inlet pipe of water tank after when you disconnect it from water
main.
------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------
1.
Do not switch on the water heater unless you established it was filled with water..
2.
Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
3.
Models without power cord, the circuit has to be supplied with a safety fuse (16A) and with inbuilt
device to ensure disconnection of all pole pieces in the conditions of over-voltage from category III.
4.
If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative
or a person with similar qualification, to avoid any risk.
5.
During the heating the appliance could produce a hissing noise (the boiling water). This is common and
does not indicate any damage. The noise gets higher with the time and the reason for this is the accumulation
of limestone. To remove the noise the appliance must be cleaned from limestone. This type of cleaning is not
covered by the warranty.
Our team would like to congratulate you on your new purchase. We hope that your new appliance shall
English

Connection to the electrical network

Dear Clients,
bring more comfort to your home
.
Instructions for use and maintenance
EN
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Svte801h

Tabla de contenido