EMERGENCY OPERATION

Under emergency situation or when remote
control is missing, you can control the unit by
pressing the on/off swith located on the indoor
unit.
• Turn on the appliance: when the unit is off, press
this button, it will start up and operate in 6th
SENSE mode.
• Turn off the appliance: when the unit is on, press
this button, the unit will stop working.
PROTECTION
Operating condition
The protective device maybe trip and stop the
appliance in the cases listed below.
Outdoor air temperature is over 24°C
Heating
Outdoor air temperature is below -10°C
Room temperature is over 27°C
Outdoor air temperature is over *43°C
Cooling
Room temperature is below 21°C
Dehumidifying Room temperature is below 18°C
*For Tropical (T3) Climate condition models, the
temperature point is 52°C instead of 43°C.
If the air conditioner runs in COOLING or DRY
mode with door or window opened for a long
time when relative humidity is above 80%, dew
may drip down from the outlet.
Noise pollution
• Install the appliance at a place that can bear its
weight in order to operate more quietly
• Install the outdoor unit at a place where the air
discharged and the operation noise would not
disturb your neighbours.
• Do not place any obstacles in front of the air
outlet of the outdoor unit lest it increases the
noise level.
Features of protection device
Wait at least 3 minutes before restarting the unit
after operation stops or changing mode during
operation. After connecting to power supply and
turning on the appliance immediately, a delay of 20
seconds may occur before it starts to operate. If all
operation has stopped, press ON/OFF button
again to restart. Timer should be set again if it has
been cancelled.
Features of COOLING mode
Anti-freezing
When the temperature of the indoor heat
exchanger drops to 0° or below, compressor will
stop working to protect the appliance.
Features of HEATING mode
Preheating
In order to prevent cool air blowing, 2-5 minutes
are necessary to preheat the indoor unit at
HEATING operation start. The indoor fan will not
work during preheating.
Defrosting
In HEATING operation the appliance will defrost
(de-ice) automatically to raise efficiency. This
procedure usually lasts 6-10 minutes. During
defrosting, fan stops running and running indicator
flashes.
After defrosting is completeed, it returns to
HEATING mode automatically.