POWER SUPPLY
400Vac 3 ~
It is necessary to install the magnetic cores (A, B and C).
You will find them in the accessory box.
In the power cable of the frequency converter, one will be installed
on the outside, as close as possible to the cable gland (A).
In the cable between the frequency converter and the motor, one
must be installed that groups all the cables (B) and another that
only groups the 3 phases without the ground (C).
Power connections
Model
[e]motion TT3-30A
0-10V INPUT
FAN
RELAY OUTPUT 2
RELAY OUTPUT 1
Power supply
Three-phase 400 V
34
PTC / NTC INPUT
PRESSURE TRANSDUCER 2
PRESSURE TRANSDUCER 1
COMMUNICATION RS485
DIGITAL INPUT 1
DIGITAL INPUT 2
DIGITAL INPUT 3
DIGITAL INPUT 4
MODBUS
Motor
Three-phase 400 Vac (DELTA connection*)
EN
FRONT PANEL
FRONT PANEL
MOTOR
400/690Vac
*For 400/690 V motors