Rated power
Nominal output current / phase
Total harmonic distortion
AC overvoltage category
5)
Current (inrush)
Maximum output fault current / duration
General data
Night-time power loss = standby consumption
European efficiency (400 / 600 / 800 / 870 V
Maximum efficiency
Safety class
EMC emission class
Pollution degree
Permitted ambient temperature
with built-in "AC disconnector" option
Permitted storage temperature
Relative humidity
Sound pressure level (600 V
Protection class
Dimensions (height x width x depth)
Weight
Inverter Topology
Protection devices
DC disconnector
Cooling principle
RCMU
DC isolation measurement
Overload performance
Active anti-islanding method
WLAN
Frequency range
Channels / power used
)
DC
)
DC
50 kW
75.8 A / 72.5 A
< 3%
228 A peak /
26.6 A rms over 3.2 ms
44.7 A / 16.24 ms
15 W
97.8 / 98.3 / 97.9 / 97.7%
98.5%
- 40 °C - +65 °C
-30 °C - +65 °C
- 40 °C - +70 °C
0 - 100%
68.4 dB(A) (ref. 20 µPa)
IP65
755 x 1109 x 346 mm
98 kg
Non-isolated transformer-
less
Integrated
Controlled forced-air ven-
tilation
Integrated
Integrated
Operating point shift
power limitation
Frequency shift method
2412 - 2462 MHz
Channel: 1-11 b,g,n HT20
Channel: 3-9 HT40
<18 dBm
3
4)
1
B
3
2)
93