10
7.
FAULTS
en
Problem
Lamp fails to light
The state of charge display
fails to light up during the
charging process
8.
STORAGE
▶ Every three months, recharge the battery up to 50 % charged.
▶ Store the lamp at temperatures between -10°C and + 40°C.
9.
CLEANING
Clean the lamp with a damp cloth.
NOTICE
▶ Do not clean the lamp whilst it is being charged.
▶ Do not use any chemical cleaners, or cleaners containing alcohol or solvents.
10. TECHNICAL DATA
Lamp
Light beam
Usage on each charge
Color temperature
Dimensions (L×⌀)
Weight
Protection class
Ambient temperature
in operation
Magnetic base
Li-ion battery
Capacity
Charging time
Power supply unit to be used
Input
Output
Troubleshooting
▶ Charge the battery.
▶ Disconnect the lamp from the power supply,
reconnect the power supply unit.
▶ Contact Hoffmann Group customer service.
Irreparable damage to the lamp
due to improper cleaning
Main light
220 lm
2,5 h
6500 k
70 × 20 mm
82 g
IP 20, IK 07
-10 °C to +40 °C
360° rotation, max. 30° inclination
3,7 V / 1100 mAh / 4,07 Wh
3 h
100 – 240 V / 50/60 Hz
5 V / 1 A
www.hoffmann-group.com
Spotlight
80 lm
5,5 h
6500 k