MESTO 3615S Instrucciones De Uso página 16

Ocultar thumbs Ver también para 3615S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
EN
Preparation
Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull the red button on the safety valve [13] until the tank is depressurised. (Fig. 3)
2. Press the pump handle [14] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 4)
3. Unscrew the pump [2] from the tank [1]. (Fig. 5)
+
To ensure the pump remains clean during storage, we recommend you attach the
pump to the pump holder [15]. (Fig. 6)
+
We recommend you mix the spraying liquid in the device or premix it in an external tank:
Fill to 1/3 with water, pour in the spraying agent, and then add more water until full.
4. Add the spraying liquid to the tank [1] (Fig. 6)
5. Screw the pump [2] into the tank [1]. (Fig. 7)
6. Swivel in the pump holder [15]. (Fig. 7)
With pump
7. Press the pump handle [14] down and turn it counterclockwise.
► The pump handle is unlocked. (Fig. 8)
8. Generate the required pressure (→ Table 2) in the tank [1]. (Fig. 9).
+
The maximum pressure should not exceed 6 bar (red line on the pressure gauge
[16], Fig. 9). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
9. Press the pump handle [14] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 4)
With filler valve
7. Connect the compressed-air hose [17] to the filler valve [18]. (Fig. 10)
► Pressure is built up (max. 6 bar).
Ensure that the initial pressure is not higher than 15 bar (218 psi).
8. When the required pressure has built up (→ Table 2), remove the compressed-air
hose [17].