OPERATING AND MAINTENANCE MANUAL
ELECTRIC CIRCULATOR PUMP SERIES PC & PCB
18.
How to adjust the position of the junction box; The above operations may only be carried out by
qualified personnel.
The junction box cannot be located in position
"X" (as shown in the figure).
www.proindecsa.com / proindecsa@proindecsa.com
The location of
the junction box
can be adjusted
according
to
the position of
different types of
installation.
Be-
fore adjustment,
confirm that the
power
switch
and water source
switch are turned
off
when
the
pump cools down
unscrew the four
points
connec-
Separate the engine section and the
ting
the
motor
and pump body.
pump section.
Service or repair may only be started after the pump has
cooled down to prevent injury from heat or hot liquid.
18
Make sure that the power
switch is turned off in case
of any necessary service.
Rotate the motor
section until the
junction box is
in the right place
and screw the
four bolts until
the motor and
pump are com-
pletely
sealed
and connected.