Levenhuk Wezzer BASE L50 Guia Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
EN
Levenhuk Wezzer BASE L50 Thermometer
The kit includes: base station, sensor, user manual, and warranty.
Also required (not included):
2 AAA batteries for the sensor
2 AAA batteries for the base station
Getting started
Base station
Open the battery compartment cover (10) and insert 2 batteries according to the
correct polarity. Close the cover.
Wait until the indoor temperature is displayed on the base station.
Sensor
Open the battery compartment cover (8). The sensor should be operated on channel 1.
Insert 2 batteries according to the correct polarity. Close the cover.
To re-establish the sensor connection manually, press RESET using a pin.
Sensor connection
Place the base station and the remote sensor within the effective transmission range.
Ensure that the channels are assigned after you set up the power supply for the base
station and all the sensors.
If the reception is successful, the display will show the temperature of the respective
outdoor sensor. If the values are not received from a channel, "—" appears on
the display. Check the batteries and try it again. Check if there is any source of
interference.
When changing batteries, replace the batteries first in the base unit, and then in all
the sensors, to re-establish the connection. If an adapter supplies power to any of the
devices, briefly disconnect the power to that device when replacing the batteries. If you
change the batteries only in one of the devices (for example, in the sensor), the signal
may not be received correctly.
The effective range may differ depending on the unit's position. Due to interference
(various remote control devices, etc.), the maximum distance between the base unit
and the sensor may be significantly reduced. In such cases, we suggest moving the
base unit and sensor a little. Sometimes it is enough to move one of these units a few
inches!
NOTE! Although the sensor is weather resistant, never place it in direct sunlight or in
the rain or snow.
Time setting
Press SET and hold it for 3 seconds. The digits that are to be set are flashing. Press MEM
to change the value, and then press SET to continue.
The setting order: 12/24h > Hours > Minutes.
Temperature units
Press SET to switch between ℃ and ℉.
History record
Press MEM to display the MAX. and MIN. temperature values.
Hold MEM to clear the MAX. and MIN. IN/OUT temperature record.
Specifications
Base station
Temperature, units of measurement
Operating temperature range (indoors)
Time format
Screen
Power supply
Dimensions
Wireless sensor
Sensor
Radio signal frequency
Radio signal radius
°F, °C
0... +50°C (+32... +122°F)
24 hours, 12 hours
monochrome
2 AAA batteries (not included)
75x37.65x105mm (2.9x1.4x1in.)
1 pc. (included)
433.92MHZ
50m (164ft)