5 Work and safety instructions

5.1 General

Trainees should only work with the circuits under the supervision of an instructor.
Observe the specifications included in the technical data for the individual
components, and in particular all safety instructions!
Wear personal safety equipment (safety glasses, safety shoes) when working on
circuits.

5.2 Electrical safety

Risk of death in case of interrupted protective earth conductor!
Risk of death from connecting power supply units in series!
Contact voltages of greater than 25 V AC or 60 V DC are not permissible.
Coming into contact with voltages of greater than 50 V AC or 120 V DC may be
fatal.
Risk of death due to electric shock!
Protect the outputs of the power supply units (output sockets/terminals) and
cables connected to them from direct contact.
© Festo Didactic 8046437
The protective conductor (yellow-green) must not be interrupted, either inside
or outside of the device.
The insulation of the protective conductor must never be damaged or
removed.
Do not connect voltage sources in series.
Only use cables with adequate insulation and electric strength.
Use safety sockets with fully shrouded contact points.
CAUTION
DANGER
Motor Technology Contactor Set