RAV RAV4406 DC Manual Del Usuario página 59

Elevador electrohidraulico de 4 columnas
Tabla de contenido

Publicidad

Some possible problems wich may arise while using the lift are listed below. Ravaglioli will not accept
any resposibility for damage people, animals and objects caused by unautorized staff using the
8. PROBLEMS
equipment. In the event of faults, you are advised to contact the technical service department in good
time to receive advice about how to carry out work and/or adjustments in maximum safety conditions,
thus avoiding the risk of damage to people, animals and objects.
Turn the main switch to "0" and lock in case of emergency and/or maintenance to the lift.
TROUBLE
The lift does not
work
The lift rises but
does not lower
Lowering speed is
very low
The motor turns
regularly but the lift
does not rise, or
rises slowly
The lift lowers but
does not lif
RAV4406 DC
POSSIBLE CAUSES
a)
Main switch in "0" position
b)
Fuse of the transformer or main protection
fuses (installed by the user) burnt
c)
Failure in the electric installation
d)
Lifting limit switch with open contacts
(jammed or broken)
e)
Cable breakage safety limit switch with
open contacts (jammed, broken or
operated by malfunction in the driving cam
controls)
f)
Cable safety actuated due to very slack
cable
g)
Cable safety actuated due to broken cable
h)
Disconnected motor thermal probe
a)
Slack cable safety actuated by obstacle
under the platform or by slack cable
b)
Malfunction of the system driving the
operating cam
c)
Failure of descent solenoid valve
a)
The flow controlvalve does not work
properly
b)
Clogged pipe
a)
Descent solenoid valve jammed in open
position
b)
Pump intake filter clogged
c)
Piston gasket damaged or worn
d)
Pump worn or damaged
a)
Rise limit switch with open contacts
(jammed or broken)
a)
Turn the switch to "I" position
b)
Replace the burnt fuses. Should the fuse
burn again, find the cause of the failure
c)
Check the efficiency of connections and
components (buttons, remote control
switch, transformer, thermal probe)
d)
Repair the limit switch or replace it
e)
Repair the limit switch taking care to check
the proper running of the control system of
the cam which operates the safety limit
swi t ch e s. R ep l ac e t he l im i t sw i tc h i f
necessary
f)
Operate directly on the remote control
switch by means of an isulated scewdriver
until the cable is tensioned
g)
Replace the cable (ask for the assistance
of the after sales service of your distributor)
h)
Wait for thermal probe to reconnect
a)
Press the rise button to tension all cables.
Remove the causes of cable slackening,
then lower the lift
b)
Repair the limit switch and check the
correct running of the control system of the
cam operating the safety limit switch.
Replace the switch if necessary.
c)
To l owe r t h e l i f t o p e ra t e t h e m a n u a l
lowering valve using the proper key. For
disassembling of the lowering solenoid-
valve see § MAINTENANCE
a)
Clean the valve (see § 7.5)
b)
Clean piston valve
a)
Clean the solenoid valve (see § 7.4)
b)
Clean the filter
c)
Replace the gasket
d)
Check pump for proper operation and
replace it if needed
a)
Repair the limit switch or replace it
0717-M001-0
REMEDIES
8
59

Publicidad

Tabla de contenido
loading

Tabla de contenido