The work area should be well ventilated.
Provide adequate lighting in the work area to allow observation of the cleaning process and the floor
area around the machine. Be sure to allow adequate room to bring work to and from the machine. Provide
sufficient clearance around the machine for fluid changeovers and servicing.
Site Preparation
Before installing, careful consideration should be given to the place of operation. Place unit on a smooth,
level surface. To the extent possible avoid installing machine in areas subject to high forklift traffic.
Reasonable precautions shall be taken to avoid damaging or puncturing the drum and tank walls.
Installation Procedure
All Models:
•
After removing from shipping carton place drum upright with open end facing up.
•
Place cleaning tank of top of drum. Mounting ring on sink bottom should insert easily into drum
and fully seat onto four mounting brackets. If the sink does not fit into drum check drum for
damage or out of roundness. If the sink cannot be made to seat fully into the drum do not use
the machine.
•
Plug pump power cord into back of electric box.
•
Raise tank cover and place link rod (Figure 2(B)) into fusible link (Figure 2(Q)) on cover. This link
is designed to melt at 165°F in case of fire. This eliminates the upper support and allows the
cover, which is held by the link rod in a slightly forward position (be sure this slightly forward
position is maintained), to drop shut. Do NOT allow any parts to remain in the parts washer that
would prevent the lid from closing. The fusible link and/or the link rod should be replaced any time
it is damaged and no longer holds the lid open.
•
Slip cloth filter bag onto drain cover. Position drain cover with filter bag in tank drain opening.
•
Fill with appropriate cleaning fluid
•
Insert 3-prong plug into a properly grounded compatible outlet.
DMD Models Only:
•
Position light (Figure 2(H)) on rear of cleaning tank. Lift lock ring and lower light onto bracket post.
Release lock ring and check that light is secure on tank.
•
Lower pump (Figure 2(D)) into drum by releasing the cable from bracket on right end of tank and
allow the pump to slowly pull cable into opening at left end of tank (Figure 3).
•
Plug light power cord into back of electric box.
Unit is now ready for use.
795-93850
INSTALLATION AND OPERATION
7 of 41
12/15/21