8. INSTALLATION DIAGRAM
**
6502/G+ TERMINAL BLOCK
LOCK RELEASE CONNECTION
*
Power up the D4L-G+/POE switches with the FA-G+, 18Vdc power supply
Each switch can be powered locally, by connecting the terminals "+" and "-" to the power supply.
The Jumper positicion of the switch must be as follow:
It can be also powered through the riser from OUT terminal at the switch placed just before
Power
should be as follows:
Columna
Riser
**
The maximum distance between the power supply and more distant device is 70m.
The maximum number of devices powered with each FA-G+ is 8 monitors or 4 entry panels.
It is required one power supply FA-G+ for every 8 devices.
***
The door lock to be connected could be an AC lock (AC transformer will be necessary, recommended TF-104) or a DC lock ( DC
power supply will be necessary, recommendedHRF-12/1,25A).
www.golmar.es
*
COLUMN
POWER
LOCAL
POWER
*
***
unit..
IN
6502/G+
OUT
. The position of the jumper