1. SAFETY CAUTIONS AND WARNINGS
- The installation and setup of this equipment must be done by an authorized installer.
- The current regulations oblige to protect the power supply by means of a thermal magnetic circuit breaker.
- All the installation conduits must distance at least 40 cm from any other installation.
- In regards of the power supply FA-G+:
- Do not tight with excessive strength the screws of the terminal block at FA-G+ power supply.
- Install the power supply in a dry and secure area, protected against water drops.
- Avoid placing the power supply close to heating sources, humid or dusty areas.
- Do not cover the power supply ventilation openings area to assure air flow circulation.
- To prevent damages, the power supply has to be strongly mounted. Use a DIN rail 46277 (8 DIN) to fix it.
- To avoid an Electrical shock, do not remove the protection cover and do not manipulate the cables connected to the power terminals.
2. SPECIFICATIONS
- TCP/IP video intercom system with technology IP-G+.
- Installation over existing ethernet network (D4L-G+/POE are required).
- Up to 98 blocks in one system.
- Up to 19 entry panels at each block.
- Up to 799 flats per each block.
- Up to 19 guard units for the general compound and 9 guard units at each block.
- Up to 32 ONVIF cameras.
3. PANEL DESCRIPTION
- Front
IK-07 and IP-65
Working temperature: -40~60ºC
Numeric Keypad
Door panel fixation
Header
Screw to fix the header
- Connections terminal block.
Exit button
N.O, N.C door release
dry contacts
(*) Anti-vandal tamper.
3
3
AP+
AP-
NA2
C2
NC2
130 º wide angle camera
White leds for night vision
Sensor IR
4,3" LCD TFT, 480x272 px.
Teclado de navegación
RFID reader
Light sensor
RJ-45 conector
NC1
NO, NC door release
C1
dry contacts.
NA1
GND
Local power supply input
+12V
IP G+
www.golmar.es