GENERAL WARNINGS
The tool must be connected to a suitable dust extraction system
RA75A - RA90A (not supplied).
The safety and accident prevention instructions are reported
in the "SAFETY INSTRUCTION" booklet which forms an
integral part of these documents. This OPERATING
INSTRUCTION MANUAL indicates the additional information
required specifically for use of the tool.
CORRECT USAGE
This tool is designed to be used as a sander. Read all the
warnings, instructions, indications provided on drawings and
specifications supplied with this tool. Failure to comply with all
the instructions provided below may cause serious injuries.
This tool is not intended to be used for metal brushing,
polishing and cutting operations. The use of this tool for
unintended applications may cause hazards and injuries to
people.
Do not use accessories that are not specifically designed for
the intended use of the tool or that have not been
recommended by the manufacturer. The fact that an accessory
can be fixed to the tool does not imply that it can be used safely.
The rated speed of the accessory must be at least equivalent
to the maximum speed specified on the tool. Using the
accessories at speeds above the rated one, may cause them to
break or be projected into the air.
The external diameter and thickness of the accessory must
match the specifications of the electrical tool. Accessories with
incorrect dimensions cannot be adequately protected or
controlled.
The configuration of accessories must match the tool. The use
of accessories that cannot be perfectly fitted on the tool may result
in imbalance, excessive vibrations and in the impossibility of
controlling the tool.
Do not use damaged accessories. Before use, inspect all the
accessories. Inspect the supporting pads and verify there are
no cracks, tears or excessive wear. If the tool or accessory
has fallen,verify that it is not damaged or install a new
accessory. After inspecting or installing an accessory, move
to a safe distance with any other person present and operate
the tool at maximum speed without load for one minute.
Damaged accessories generally break during this test period.
PARTS OF THE TOOL
1 - Identification plate
2 - Compressed air on/off lever
3 - Speed control
4 - Tool body
5 - Compressed air connection
6 - Suction cowling
7 - 29 mm. int. Ø suction pipe connection
8 - Velcroed abrasive disc backing pad
9 - Spanner
10 - Dust extraction flow control
STARTING UP
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having
been damaged during storage or transport;
- the tool is complete; check that the number and type of components
comply with that reported in this instruction booklet;
- the available compressed air production and distribution plant is
capable of satisfying the requirements reported on the tool's
identification plate.
ASSEMBLING THE TOOL
Assemble the compressed air connection (not supplied) by
screwing it into its seating (5).
COMPRESSED AIR CONNECTION
The tool is supplied without the compressed air connection; the
user can use either a quick release coupling or hose type
9