AC Output Connection
To avoid overloading your Inverter, be sure to match the power requirements of the equipment you plan to run at any one
time (add their total watts) with the output wattage capacity of your Inverter model. When figuring the power requirements
of your equipment, do not confuse "continuous" wattage with "peak" wattage ratings. Most electric motors require extra
power at start-up ("peak" wattage) than required to run continuously after start-up, sometimes over 100% more. Some
motors, such as in refrigerators and pumps, start and stop intermittently according to demand, requiring "peak" wattage at
multiple, unpredictable times during operation.
• DoubleBoost™ Feature: Tripp Lite Inverters deliver up to twice their nameplate rated wattage for up to 10 seconds,*
providing the extra power needed to cold start heavy-duty tools and equipment.
• OverPower™ Feature: Tripp Lite Inverters deliver up to 150% of their name plate rated wattage for up to 1 hour,*
providing plenty of reserve power to reliably support tools and equipment longer.
* Actual duration depends on battery age, battery charge level and ambient temperature.
Troubleshooting
Try these remedies for common Inverter problems before calling for assistance. Call Tripp Lite Customer Service at (773)
869-1234 before returning your unit for service.
SYMPTOM
No AC Output
(All Indicator Lights Are OFF)
Red Battery Indicator Light Is
Rapidly Flashing
(¼ Second Flashes)
Red Load Indicator Light Is
Rapidly Flashing
(¼ Second Flashes)
Connected Equipment
Experiences Buzzing Sound Or
Picture Distortion
Inverter Output Seems Intermittent Loose cable connections.
PROBLEMS
Operating Mode Switch is
set to "OFF."
User-supplied UL-listed
external DC input fuses
have blown.
Unit has shut down due to
excessive battery
discharge.
Unit has shut down due to
overload.
Audio/Video interference.
11
CORRECTIONS
Set Operating Mode Switch to "ON" or "REMOTE."
Replace fuses.
Run your engine to raise battery voltage. Check
external battery connections and fuse. Reset by moving
Operating Mode Switch to "OFF." Wait one minute and
switch to "ON" or "REMOTE."
If unit remains in shutdown mode after several attempts
to reset contact Tripp Lite Customer Service for
assistance.
Reduce load. Reset by moving Operating Mode Switch
to "OFF." Wait one minute and switch to "ON" or
"REMOTE."
If unit remains in shutdown mode after several attempts
to reset contact Tripp Lite Customer Service for
assistance.
Reposition equipment antennas and Inverter.
Check and secure all connections.