Operation

Switch Modes
Switch between the following operating modes as appropriate to your situation:
ON: Move the switch to
the ON position to have
your Inverter provide
connected equipment
with AC power by
converting DC power from an attached
battery.

Indicator Lights

Your Inverter is equipped with a simple, intuitive, user-friendly set of indicator lights.
BATTERY HIGH/MED/LOW LEDs: If the operating
mode switch is in the ON or REMOTE position, the LEDs
indicate the approximate charge level and voltage of your
connected battery bank and alert you to several fault
conditions.
LED Function with Switch in ON or REMOTE Position
Approximate Battery Charge Level*
Indicator Illuminated
1
Green
2
Green & Yellow
3
Yellow
4
Yellow & Red
5
Red
6
Flashing Red (2/second) 1%–20%
7
Flashing Red (4/second) 0% (Inverter
* Levels listed are approximate. Actual conditions vary depending
on battery condition and load. ** Inverter shutdown protects
battery against damage due to excessive discharge.
OFF: Move the switch
to the OFF position to
shut down the Inverter
completely, preventing
REMOTE
it from drawing power
from the battery. Leave the switch
in the OFF position when not using
connected equipment to prevent
battery drain. Also use this setting to
automatically reset the unit if it shuts
down due to overload or overheating.
First remove the excessive load
or allow the unit to sufficiently cool
(applicable to your situation). Switch
REMOTE
to OFF, then back to ON. If unit fails to
reset, remove additional load or allow
the unit to cool further and try again.
REMOTE
Battery Capacity
91%–Full
81%–90%
1
2
61%–80%
41%–60%
21%–40%
4
5
shutdown)**
7
REMOTE
REMOTE
REMOTE
LOAD LOW/MED/HIGH LEDs: These three lights show the
power demand on your Inverter.
LED Function with Switch in ON or REMOTE Position
Indicator Illuminated
1
Green
2
Green & Yellow
3
Yellow
4
Red
5
Flashing red (2/second) OVERLOAD
Flashing red (4/second) OVERLOAD
3
6
All three lights off
6
* Levels listed are approximate and vary with application.
** Inverter shutdown protects inverter, batteries and equipment
from possible damage due to overload conditions.
Fault Condition
LEDs Illuminated
1
All three lights
flash slowly*
*Approximately ½ second on, ½ second off. See
Troubleshooting section. Inverter shutdown protects
battery against damage due to excessive discharge.
5
REMOTE: Move the
switch to the REMOTE
position to control your
Inverter at a distance
with a wired remote
control module (Tripp Lite Model #
APSRM4; sold separately). Consult
the remote control module owner's
manual for more information.
Load Level*
0%-50%
51%-75%
76%-100%
1
101%-125%
4
(Inverter has
shutdown)**
Inverter off
Fault Condition
Excessive discharge
(Inverter shutdown)
REMOTE
REMOTE
2
3
5
6
1