SPECIFICATIONS
Cat. No. ..................................................... 3622-20
Volts.............................................................. 12 DC
Battery Type .................................................M12™
Charger Type................................................M12™
Laser............................................................Class 2
Lines Max Power ................................. P
Points Max Power................................ P
Pulse Frequency..........................................10 KHz
Pulse Duration Normal Mode ................. T
Pulse Duration Power Save.................... T
Wavelength.......................................... 510-530 nm
Lines Beam Divergence ................................. 1 rad
Points Beam Divergence .......................... 0.5 mrad
Storage Temp .................................... -4°F to 120°F
Working Range .................................................125'
Range with Detector .........................................165'
Accuracy ...............................................±1/8" @ 33'
Settle Time ......................................... < 3 Seconds
Tripod Mount ..................................1/4"-20, 5/8"-11
Ingress Protection............................................ IP54
Drop Rating .......................................................1 m
Leveling ............Auto ±°4 side to side, front to back
Recommended Ambient
Operating Temperature .................. 14°F to 104°F
FUNCTIONAL DESCRIPTION
1. Laser apertures
2. Laser mode indicator
3. On/Off dial
4. Pivot Bracket
1
1
1
1
7
6
5
10
9
≤ 7 mW
AVG
≤ 1 mW
AVG
≤ 80 µs
p
≤ 50 µs
p
5. Micro adjust
6. Fuel gauge
7. Mode button
2
CAT. NO. 3622-20
12 V
SER.
IEC 60825-1:2014-05 t
P
≤ 7mW @ 510nm - 530nm LINES
AVG
CROSS LINE & PLUMB POINTS
P
≤ 1mW @ 510nm - 530nm POINTS
LASER
AVG
COMPLIES WITH 21 CFR 1040.10 AND 1040.11
Milwaukee Tool, Brookfield, WI 53005 USA
EXCEPT FOR CONFORMANCE WITH IEC 60825-1
WARNING
AVERTISSEMENT
ADVERTENCIA
ED. 3., AS DESCRIBED IN LASER NOTICE NO. 56,
DATED MAY 8, 2019. THIS DEVICE COMPLIES
To reduce the risk of injury, user must read operator's manual. Use M12 batteries.
WITH PART 15 OF THE FCC RULES. OPERATION IS
Pour minimiser les risques de blessures, l'utilisateur doit lirele manual. Utiliser des piles M12 .
SUBJECT TO THE FOLLOWING TWO CONDITIONS:
Para reducir el riesgo de lesiones,
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
el usuario debe leer el manual.
INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED,
Utilice baterías de M12 .
INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Made in China
8. Threaded inserts
9. Magnets
10. Nail/Screw hole
8
WARNING
cific charging instructions, read the operator's
manual supplied with your charger and battery.

Removing/Inserting the Battery

To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
WARNING
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
WARNING
may be hazardous.
Use power save mode to extend the battery run
time. Power save mode is indicated by dimmed laser
beams and the Mode indicator pulsing. Visual range
is decreased in power save mode. To turn power save
3
mode ON or OFF, press and hold Mode button for 3
seconds. The tool will automatically switch to power
save mode if less than 7% of battery charge remains.
4
To determine the amount of charge left in the battery,
turn the tool ON. The Fuel Gauge will light up for 2-3
seconds. When less than 10% of charge is left, 1 light
on the fuel gauge will flash 4 times.
≤ 80 μs MAX OUTPUT
To signal the end of charge, 1 light on the fuel gauge
P
will flash 8 times and the tool will not run. Charge
the battery pack.
If the battery becomes too hot, the fuel gauge lights
will flash and the tool will not run. Allow the battery
to cool down.
*When automatically switched to power save mode
due to low battery, the tool cannot be switched back
to normal mode until the battery is charged/replaced.
WARNING
laser before starting an operation. Injury/damage
may occur if the laser falls.
Mounting/Adjusting the Laser Level
The pivot bracket can be used to mount the laser
level in multiple ways:
• Use the embedded magnets to secure the laser level
to steel studs, steel beams, etc.
• Use the keyhole slot to hang the laser level on the
wall with a nail or screw.
• Set the laser level on a flat surface.
3
SYMBOLOGY
Volts
Direct Current
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
Magnets
Read operator's manual
ASSEMBLY
Recharge only with the charger
specified for the battery. For spe-
Always remove battery pack before
changing or removing accessories.
Only use accessories specifically
recommended for this tool. Others
Power Save
Fuel Gauge
To reduce the risk of injury or dam-
age, securely mount/attach the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3622-20

Tabla de contenido