CALCULATION OF THE THERMAL POWER

There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is 30 kcal/h per m
external temperature of 0°C).
given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
let's suppose one wishes to heat a room of 150 m
W/m
= 5250 W or 5,25 kW. as main heating, a 8 kW device is therefore sufficient.
3
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity

DIsPOsAL

INFORMaTION FOR MaNagEMENT OF ElECTRIC aND ElECTRONIC aPPlIaNCE WasTE CONTaININg baTTERIEs OR
aCCUMUlaTORs
This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful
life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste.
Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained
in the product. For the purpose of preventing damage to health or the environment, users are kindly asked to separate this equipment and/
or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask
your local dealer to collect the waste electric or electronic appliance under the conditions and following the methods provided by national
laws transposing the Directive 2012/19/EU.
separate waste collection and recycling of unused electric and electronic equipment, batteries and accumulators helps to save natural
resources and to guarantee that this waste is processed in a manner that is safe for health and the environment.
For more information about how to collect electric and electronic equipment and appliances, batteries and accumulators, please contact your
local Council or Public authority competent to issue the relevant permits.
46
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
Approximate combustion value
Unit
kcal/h
kg
3600
kg
1850
kg
4000
kg
4800
kg
7700
kg
6780
m
7800
3
l
8500
kW/h
860
ENgLIsH
.
3
Required quantity in relation to
1 kg of dry wood
kW
4.2
2.2
5.0
5.6
8.9
7.9
9.1
9.9
1.0
3
(for an
x 35
3
1,00
1,95
0,84
0,75
0,47
0,53
0,46
0,42
4,19