Boiler Description - Beretta Mynute S 24 C.A .I. E Instrucciones De Instalacion Y Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
ENGLISH
INSTALLER
EN
1 - GENERAL SAFETY DEVICES
Our boilers are built in our plants and checked down to
the smallest detail in order to protect users and fitters from
injury. After working on the product, qualified personnel must
check the electrical wiring, in particular the stripped part of
conductors, which must not stick out from the terminal board,
avoiding possible contact with live parts of such conductor.
This instruction manual, together with the user manual, are
integral parts of the product: make sure that they remain with
the appliance, even if it is transferred to another owner or
user, or moved to another heating system. In case of loss
or damage, please contact your local Technical Assistance
Service for a new copy.
Boiler installation and any other assistance and maintenance
operation must be carried out by qualified personnel
according to current local and national regulations.
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
This appliance should not be operated by children younger
than 8 years, people with reduced physical, sensory or
mental capacities, or inexperienced people who are not
familiar with the product, unless they are given close
supervision or instructions on how to use it safely and are
made aware by a responsible person of the dangers its use
might entail. Children must not play with the appliance. It is
the user's responsibility to clean and maintain the appliance.
Children should never clean or maintain it unless they are
given supervision.
This boiler must only be used for the application it was designed
for. The manufacturer declines all contractual and non-
contractual liability for injury to persons or animals or damage
to property deriving from errors made during installation,
adjustment and maintenance and from improper use.
After removing the packaging, make sure the content is in
good conditions and complete. Otherwise, contact the dealer
from who you purchased the appliance.
When the product reaches the end of its life it should not be
disposed of as solid urban waste but should be brought to a
separated waste collection facility.
The safety valve outlet must be connected to a suitable
collection and venting system. The manufacturer declines
all liability for any damage caused due to any intervention
carried out in the safety valve.
Dispose of all the packaging materials in the suitable
containers at the corresponding collection centres.
Dispose of waste being careful not harm human health
and without employing procedures or methods which may
damage the environment.
The ventilation openings are vital for correct combustion.
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut off and
the Technical Assistance Service must be contacted immediately
- the operation pressure of the hydraulic system must be within
1 and 2 bar, and therefore, must no exceed 3 bar.If necessary,
reset the pressure as indicated in the paragraph entitled "Filling
the system"
- if the boiler has not been used for a long time, it is recommended
that the Technical Assistance Service performs, at least, the
following operations:
In some parts of the manual, some symbols are used:
WARNING = for actions requiring special care and
adequate preparation
FORBIDDEN = for actions THAT MUST NOT be performed
4
All manuals and user guides at all-guides.com
- boiler maintenance must be carried out at least once a year.
For safety, always remember that:

2 - BOILER DESCRIPTION

Mynute S C.A.I. E is a wall-mounted type B11
and the production of domestic hot water. This type of appliance
cannot be installed in bedrooms, bathrooms or showers, or in
rooms with open flues without adequate ventilation.
The Mynute S C.A.I. E boiler is fitted with the following safety
devices:
- Safety valve and water pressure switch intervening in cases of
- Temperature limit thermostat intervening by putting the boiler into
- Fumes thermostat intervenes by blocking the boiler into a safety
The flue gas thermostat not only intervenes for a fault in the
combustion products outlet system, but also with various
atmospheric conditions. One can therefore try to start up the boiler
again after waiting a short while (see first ignition section).
After repairs carry out a trial ignition.
• turn "off" the main switch of the appliance and the general
switch of the system
• close the gas and water taps on both the heating and domestic
hot water circuits
• drain the heating and domestic hot water circuits to prevent
freezing
This should be booked in advance with the Technical Assistance
Service.
It is dangerous to activate electrical devices or appliances,
such as switches, home appliances, etc., if you smell gas or
fumes. In the event of gas leaks, ventilate the room opening
doors and windows; close the gas general tap; contact the
qualified personnel from the Technical Assistance Service
immediately
Do not touch the boiler while barefoot or if parts of your body
are wet or damp
Before cleaning operations, disconnect the boiler from the
main power supply by turning "OFF" the two position system
switch and the main control panel switch
Do not modify safety and adjustment devices without the
manufacturer's permission and relative instructions
Do not pull, disconnect or twist the electric cables coming
out of the boiler even when it is disconnected from the main
power supply
Avoid covering or reducing the size of ventilation openings of
the installation room
Do not leave inflammable containers and substances in the
installation room
Keep packaging materials out of reach of children.
Do not cover or reduce the size of the ventilation openings
in the room where the boiler is installed. The ventilation
openings are vital for correct combustion.
insufficient or excessive water pressure (max 3 bar-min 0.7 bar).
safety stop if the temperature in the system exceeds the limit
according to current local and national regulations
standstill status if there is a spillage of combustion products in
the hood; it is located on the right hand tile of the vent-damper
draught breaker device Intervention of safety devices indicates
a potentially dangerous boiler malfunction; contact the technical
assistance service immediately.
Repeated intervention of the fumes thermostat signifies
evacuation of combustion products into the boiler room
with possibly incomplete combustion and formation of
carbon monoxide, a highly dangerous condition. Call the
technical assistance service immediately.
The boiler must never be put into service, not even
temporarily, if the safety devices are not working or have
been mishandled.
Safety devices must be replaced by the technical assistance
service, using original manufacturer parts only.