5.Refrigeration/ freezing temperature display lamp
Display the temperature set up for the refrigeration/ freezing chamber, and
display in a circular way at the frequency of 1 Hz.
6.Refrigerating chamber indicator lamp
When the temperature set up for the refrigerating chamber is displayed, and
the refrigeration chamber indicator lamp will turn on.
7.Freezing chamber indicator lamp
When the temperature set up for the freezing chamber is displayed, the
freezing chamber indicator lamp will turn on.
8.Refrigeration/ freezing chamber temperature setting key
Press "Room" key to select "Refrigeration", and the refrigeration temperature
display area will display originally set temperature, and flicker at the fre-
quency of 1 Hz; press "Temperature" key for every one more time, the setting
will change in a circular way as per 2----> 3 ... ----> 8 ----> OF----> 2----> 3 ... ----> 8
----> OF; if there is no key-pressing operation within 5s or the "Room" key is
pressed once more to enter into the setting of other room, the indicator
lamp will stop flickering, and the setting will take effect. lf the refrigerator is
set up to be OF, the refrigerator will stop refrigerating. Press "Room" key to
select "Freezing", and the freezing temperature display area will display
originally set temperature and flicker at the frequency of 1 Hz; press
"Temperature" key for every one more time, the setting will change in a
circular way as per -25----> ... ----> -16----> -15----> -25-> ... -> -16-+ -15; if there is
no key-pressing operation within 5s or the "Room" key is pressed once more
to enter into the setting of other room, the indicator lamp will stop flickering,
and the setting will take effect.
9.Chamber selection setting key
Touch "Room" key lightly, and the current room indicator lamp will turn on
and flicker at the frequency of 1 Hz. Press "Room" key for every one more
time, the indicator lamp will change circularly between refrigeration
chamber and freezing chamber. lf there is no key-pressing operation within
5s, the setting will be defaulted confirmed and will take effect.
Fault Code Display
Fault display
code RS
FS
Fd
ES
FF
uc
Failure of the sensor in the refrigeration chamber
Failure of the sensor in the freezing chamber
Failure of sensor for defrosting of freezing chamber
Failure of ambient temperature sensor
Communication failure
16
Fault items
Fan failure