Gas and electric requirements

IMPORTANT: If not already present, install a gas shut-
off valve in an easily accessible location. Make sure all
users know where and how to shut off the gas supply
to the range.
A metal flex line or fixed metal pipe shall be used to
connect gas to the appliance. If a metal gas line
cannot be used, consult your local certified electrician
or local electric codes for proper grounding.
Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected
to propane gas, ensure that the propane gas supply
tank is equipped with its own high pressure regulator
in addition to the pressure regulator supplied with the
range.
inches (mm)
Range model
All Harmony series
36''/ 48'' Grand series
60'' Grand series
C
C
D
D
E
E
X
X
Gas zone A
Electric zone B
4'' (102)
6'' (152)
4'' (102)
6'' (152)
4'' (102)
6'' (152)
The gas and electrical supplies must be within the
zones as indicated in the image below.
A manual gas shut-off valve must be installed external
to the appliance, in a location accessible from the
front, for the purpose of shutting off the gas supply.
The supply line must not interfere with the back of the
unit.
The range is supplied with its own pressure regulator
that has been permanently mounted within the range
body.
For nearly-flush installation to the back wall, the gas
supply line and electrical cord should not go above 9''
(229 mm) above the floor.
When the power supply cord or conduit is connected
to the mating receptacle or terminal block cover, the
combined plug/receptacle or terminal block cover/
conduit connector should protrude no more than 2''
(51 mm) from the rear wall.
30", 36", 48", 60"
30", 36", 48", 60"
30", 36", 48", 60"
(762, 914, 1219, 1524)
(762, 914, 1219, 1524)
(762, 914, 1219, 1524)
B
B
A
A
C
C
L
L
C
C
L
L
X
5'' (127)
N/A
8'' (203)
4'' (102)
8'' (203)
4'' (102)
8"
8"
8"
(203)
(203)
(203)
X
X
C
D
N/A
2'' (51)
3'' (76)
2'' (51)
3'' (76)
1'' (25)
E
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Professional pro harmony serieProfessional pro grand prd364wdgcProfessional pro grand prd364wdguProfessional pro grand prd364wigcProfessional pro grand prd364wiguProfessional pro grand prd364wlgc ... Mostrar todo