The bracket may be attached to a solid wood surface
having a minimum wall thickness of ¾'' (19 mm).
•
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
•
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood surface.
•
Use appropriate anchors when fastening the mounting
bracket to any material other than hardwood or metal.
•
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Installing the anti-tip bracket
1. Locate the anti-tip bracket in the literature packet,
inside the box that was on top of the appliance.
2. Place bracket on the floor in a position shown below.
The bracket may be placed on either the left or the
right side.
3. For walls, wall studs, or floors composed of solid
wood or metal, drill 1/8'' (3 mm) pilot holes.
4. Secure to floor and/or wall stud using the (4) 1½''
(38 mm) cross-head screws provided.
5. Later, when the unit is installed, the adjustable leg will
slide under the bracket.
Anti-tip bracket location for 30'', 36'', and 48'' models
C L
x x
Model
30'' Harmony
36'' Harmony
36'' Grand
48'' steam models only
48'' all other models
C L
C L
x x
Value for 'X'
1-3/4'' (45 mm)
2-3/16'' (56 mm)
3-7/8'' (98 mm)
1-5/8'' (41 mm)
1-3/4'' (45 mm)
Anti-tip bracket location for 60'' models
C L
x x
Model
60''
Gas requirements and connection
9 CAUTION
•
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than ½
psig (3.5kPa.).
•
When connecting unit to propane gas, make certain
the propane gas tank is equipped with its own high
pressure regulator in addition to the pressure
regulator supplied with the appliance. The pressure of
the gas supplied to the appliance regulator must not
exceed 14" water column (34.9 mbar).
9 WARNING
DO NOT use a flame of any kind to check for gas leaks.
IMPORTANT: Do not ground to a gas pipe.
Verify the type of gas being used at the installation site.
Make certain the range matches the type of gas available
at this location.
The gas supply connections shall be made by a competent
technician and in accordance with local codes or
ordinances. In the absence of local codes, the installation
must conform to the National Fuel Gas Code ANSI
Z223.1/NFPA54- current issue.
High altitude
•
This appliance has been tested for operation up to an
altitude of 10,100 ft (3,078 m) elevation above sea
level.
•
A high altitude kit is required for natural gas above
5,400 feet (1,646 m) elevation above sea level, and for
propane (LP) above 10,000 feet (3,048 m) elevation
above sea level.
C L
C L
x x
Value for 'X'
2'' (51 mm)
12