Turn the depth adjusting knob
aligning the appropriate number with the red arrow on
the tool.
Plunge Depth Fine Adjustment (Fig. F)
The fine adjustment is used to eliminate possible tolerances in
the size of the biscuit slots.
1. Raise the fence
6
to its uppermost position as
described above.
2. Insert the T20 Torx key as shown and adjust the plunge
depth as required by turning the screw
to decrease the plunge depth). Each full turn causes a
change in depth of 1 mm.
3. Check the setting by making a trial cut in a piece of
scrap wood.
Anti‑Slipping Pins (Fig. G)
The anti‑slipping pins
7
help to reduce the tendency of the
biscuit jointer to slide to the left when cutting. When working
on visible parts of the workpiece, you may want to retract them
in order to avoid scratching.
1. To retract the pins, rotate them slightly clockwise using a
flat screwdriver.
2. To use the pins again, rotate them slightly counterclockwise.
Replacing the Blade (Fig. H, I, J)
WARNING:
•
Make sure that the teeth of the cutter point in
counterclockwise direction as shown (Fig. I).
•
After replacing the blade, always check the cutting
depth and adjust if necessary.
•
Do not use blades or larger or smaller diameter than
recommended. For the proper blade rating refer to the
technical data.
•
Use only blades specified in this manual complying
with EN847-1.
1. Loosen the four T20 Torx headed screws
plate and take off the cover.
2. Depress the spindle lock
turning it counterclockwise.
3. Replace the blade making sure the teeth of the cutter point
in a counterclockwise direction.
4. Tighten the flange securely by turning it clockwise while
keeping the spindle lock depressed.
5. Mount the cover plate and tighten the hex screws.
Dust Extraction (Fig. K1, K2, K3)
Using the appropriate adapter, you can connect either a dustbag
or a dust extractor.
Dust Extractor
1. Insert the appropriate adapter
extraction outlet
5
.
8
into the required position,
(turn clockwise
23
15
from the base
and remove the flange by
10
16
or
17
into the dust
2. Connect the dust extractor hose to the adapter.
Dustbag
1. Insert the straight adapter
outlet
5
.
2. Attach the dustbag
18
3. Whenever possible, connect a dust extraction device
designed in accordance with the relevant regulations
regarding dust emission.
Attaching an AirLock
Extractor (Fig. K3)
WARNING: When using dust extraction, empty vacuum
before work begins and often during work. Use care in
disposing of dust. Dust can be hazardous to health if
inhaled, ingested or in contact with the skin. Materials in
fine dust can be explosive.
Your tool is compatible with the D
system. The AirLock™ allows for a fast, secure connection
between the AirLock™ connector
adapter
16
.
1. Remove the battery.
2. Ensure the collar on the AirLock™ connector is in the
unlock position. (Refer to Figure K3.) Align notches
collar and AirLock™ connector as shown for unlock and
lock positions.
3. Push the AirLock™ connector onto the adapter
connector point.
4. Rotate the collar to the locked position.
nOtE: The ball bearings inside collar lock into slot and
secure the connection.The power tool is now securely
connected to the dust extractor.
nOtE: The sleeve of the dust extraction port can be
removed if damaged and replaced by the user. The sleeve is
available as an optional accessory and can be replaced using
a screwdriver.
OPERATION
Instructions for Use
WARNING: Always observe the safety instructions and
applicable regulations.
WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
Proper Hand Position (Fig. V)
WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.
WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the auxiliary
handle
3
, with the other hand on the main grip
16
into the dust extraction
to the adapter.
Compatible Dust
™
WALT AirLock™ connection
e
21
and the straight
19
.
EngLIsh
22
on
39