Maintenance And Troubleshooting - Master Pumps MPXP801 Traducción De Las Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BOOSTER SETS MASTER PUMPS are self-
priming. Therefore, it is possible to start them
without filling the suction pipe with water. However,
it is still necessary to fill the pump body. The priming
operation requires a few minutes. It may also
be necessary to fill the pump body with water
several times, according to the length and diameter
of the suction pipe.
If the electropump is not used for a long period of
time, it is necessary to repeat all the operations
described above before starting the pump.
6 Adjustment of the pressure switch
This setting can be done only if the facility is free of
defects in the table (page 7).
The switch is normally set between 1.4 & 2.8 bar.
To change this setting, it should follow the following
procedure:
To change both minimum and maximum pressure,
turn the screws A (clockwise to increase) the gap
between the two pressures do not vary.
If the pump runs constantly, even without taking
water in the system, this means that the maximum
pressure the switch is too high.
To reduce the Différenciel pressure, loosen the
screw B.

7 Maintenance and troubleshooting

disconnected from electric
DANGER
Electric shock risk
advisable to periodically check the pressure
supplied and current absorption. A reduction of the
pressure may indicate that the electropump is worn.
Sand and other corrosive materials present in the
delivery fluid cause a rapid wear and a reduction of
performance.In this case, it is advisable to use a
filter and select an appropriate filter cartridge
according to the application. An increase in current
absorption indicates the presence of abnormal
mechanical friction in the pump and/or the motor.
Make sure the machine is
power supply,
before performing
maintenance operation.
To avoid problems, it is advisable to regularly check
the pre-load pressure in the tank. At this point,
disconnect the pump from the mains and open the
water supply to remove the pressure from the
system. Then, measure the pre-load pressure using
the valve on the rear side of the tank. Perform the
measurement with an independent pressure gauge.
Pressure should be equivalent to 1.5 bar. Correct
the value if it is incorrect.
If the electropump is not going to be used for a long
period of time (i.e. one year), it is advisable to empty
it completely (by opening the drain cap, see Fig. 1 n.
10), rinse it with clean water and store it in a dry
location, where it can be protected from frost.
SERVICE DEPARTMENT
_ Damaged switches must be replaced by our after-
sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his agent
to avoid a hazard.
AFTER-SALES SERVICE AND APPLICATION
SERVICE
Our after-sales service responds to your questions
concerning maintenance and repair of your product
as well as spare parts. Exploded views and
information on spare parts can also be found
under:www.eco-repa.com
MASTER PUMPS application service team will
gladly answer questions concerning our products
and their accessories : sav@eco-repa.com
STORAGE
_ Thoroughly clean the whole machine and its
accessories.
_ Store it out of the reach of children, in a stable and
secure position, in a cool and dry place, avoid too
high and too low temperatures.
_ Protect it from exposure to direct sunlight. Keep it
in the dark, if possible.
_ Don't keep it in plastic bags to avoid humidity
build-up.
GUARANTEE
Refer to the enclosed guarantee conditions
for the terms and conditions of guarantee.
ENVIRONMENT
22
Should your machine need
replacement after
extended use, do not put it in
the domestic waste but
dispose of it in an
environmentally safe way.