Operation
OPERATION
Risk of electric shock. Do not handle a
pump or pump motor with wet hands or when
standing on wet or damp surface, or in water.
1. Shaft seal depends on water for lubrication. Do
not operate pump unless it is submerged in
water as seal may be damaged if allowed to run
dry.
2. Motor is equipped with automatic reset thermal
protector. If temperature in motor should rise
unduly, switch will cut off all power before dam-
age can be done to motor. When motor has
cooled sufficiently, switch will reset automatically
and restart motor. If protector trips repeatedly,
pump should be removed and checked as to
cause of difficulty. Low voltage, long extension
cords, clogged impeller, very low head or lift, or
a plugged or frozen discharge pipe, etc., could
cause cycling.
Bracket
Pin
Float
Rod
NOTICE: For Model FPOS1800LTS, see instructions included with replacement switch, Part Number FPS17-66.
For parts or assistance, call Flotec Customer Service at
All manuals and user guides at all-guides.com
3. Pump will not remove all water. If operating a
Vertical Switch Assembly
Switch
Housing
Bracket
Mounting
Screws
Rod Stop
pump manually, and suddenly no water comes
out of the discharge hose, shut off the unit
immediately. The water level is probably very low
and the unit has broken prime.
Risk of electric shock. Before attempt-
ing to check why unit has stopped operating,
disconnect power from unit.
1
Mount the bracket onto the switch
housing.
Slip the float and then the rod stop
2
onto the rod past the second nib.
3 Insert the rod assembly up into the
switch housing and lock into place
with the pin.
NOTICE: Be sure the pin holds the
rod into the switch housing or the
pump will not shut off.
4 Attach the switch to the pump as shown.
Tethered Float Switch
Do Not Change the
preset tether length.
3-1/2"
(89 mm)
1-800-365-6832
4