Description
Weight version HRS-E with flow control

9. First Use

The pressurized cup spray gun is supplied fully assembled and ready for
operation.
After unpacking, check:
■ Pressurized cup spray gun damaged
■ Scope of supply complete (see chapter 5)

Explosion risk

The use of unsuitable compressed air hoses may cause explosions.
→ Only use solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with permanent pressure resistance of
minimum 20.0 bar,, inner diameter of minimum 9 mm and bleeder re-
sistance of < 1MOhm, such as SATA air hose (Art. No. 53090).
Notice!
Use a compressed air connection with 1/4" outer thread or suitable
SATA connection nipple.
Use clean compressed air, for example with SATA filter 484 (Art. No.
92320).
■ Check that all screws are screwed tight.
■ Connect compressed air supply line to air connection [1-12].

10. Normal Operation

Before using the pressurized cup spray gun, the manufacturer must be
consulted regarding the suitability of the specific cleaning agents and
preservatives.
30
Warning!
Variation with aluminium
pressure cup
1300 g
45.9 oz.