DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow capacity pump is compatible with mineral and synthetic oils and suitable for
large installations with long length piping supplying several fluid outlets simultaneously.
This pump can be mounted on the wall, with wall mounting bracket (Part. No. 360140, 360139), or directly on a drum or tank, using a suction
tube of a suitable length.
WARNINGS
WARNING: Read all instruction manuals, tags, and labels
!
before operating the equipment. This equipment is for
professional use only.
• The use of non compatible fluids may cause damage in the pump
and serious personal injury. This equipment is not intended for use
with fluids that fall within the Group 1 fluid as defined that are
explosive, extremely flammable, highly flammable, flammable, very
toxic, toxic, oxidizing or where the vapor pressure if greater than
0,5 bar (7 psi) above the pressure atmospheric at the maximum
allowable temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure
• A direct hit against the human body may result in an injury.
INSTALLATION
These pumps can be installed directly on a drum or tank. However, we
recommend installation with a wall-mounting bracket (360140 / 360139).
They can be installed in three different ways:
a. Wall mounting with bung adapter. Insert the pump through the
wall bracket 360139 and attach it with the bung adapter 360002
(Fig. 2).
b. Wall mounting with screws. Insert the pump through the wall
bracket 360140 and fix it with 4xM8 screws (Fig. 3).
C. Adjustable drum or tank mounting, using bung adapter 360002.
Screw the proper suction tube (see Fig. 4) to the foot valve of the
pump. Screw the nut of the bung adapter to the 2" opening of the
cover. Insert the suction tube through the nut and secure it with the
star nut at the desired height.
2
853 825 R. 03/22
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
of 12 bar (170 psi).
Fig. 3
360140
Pump
535830 / 535880
535831 / 535881
535810
535811
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of this
unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only Samoa Industrial, S.A.
genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identification labels may invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should
be suitable for the maximum possible pressure generated by the
pump/air motor. If the systems cannot be designed to take the
maximum pressure produced by the pump, safety valves or diverter
valves should be fitted.
Suction tube
Drum
753241
753243
Included
Included
Fig. 2
360002
360139
Fig. 4