6. Preparation for use

i) Place EDDYTHERM 2x in the horizontal position on a stable surface.
ii) Connect the mains plug to a suitable mains supply.
iii) Follow these steps to install the swivel arm:
› Attach the protection plate (4) to the side post to prevent damage.
› Install the swivel head (1) and the swivel body (2) on the lefthand
side post of the heater.
› Install the large top yoke [55 x 55 mm / 2 11/64" x 2 11/64"] in
the swivel head. Adjust the swivel body so that there is no visible
gap (A) between the side post and the yoke.
› Tighten the four screws (3) of the swivel body [maximum torque 5
Nm].
› Turn the screw (5) on top of the swivel head to position the top
yoke. The top yoke must contact as much of the upper surface of
the right-hand side post (B) as possible. Noise during operation
could indicate that the top yoke is not positioned properly.
 The yoke adapter is required when either of the smaller yokes
[28 x 28 mm / 1 7/64" x 1 7/64" or 14 x 14 mm / 35/64" x
35/64"] is installed. Install the yoke support and the yoke
together in the swivel head. If necessary, rotate the swivel head
to provide better access.
 The swivel body (2) can remain on the heater at all times.