v) For workpieces that do not fit over the inductive coil, follow these
steps:
› Choose the larger of the three yokes that fit through the internal
diameter of the workpiece.
› If necessary, remove the top yoke from EDDYTHERM 2x.
› Verify that the protective film has been removed from the
underside of the small or medium yoke if it is to be used for the
first time.
› Slide the workpiece onto the yoke that you have selected.
› Position the yoke on EDDYTHERM 2x with the bright underside
resting evenly on the two vertical supports.
vi) If you will use TEMP MODE, plug the temperature probe into the
connector on the left side of the heater. Place the magnetic end
of the probe on the inner ring of the bearing or on the innermost
surface of the workpiece.
vii) Use the power switch on the left side to switch EDDYTHERM 2x on.
viii) Observe the self-test of the display and signal tone.
7. Operation
7.1 Function of display
A
B
The main display shows the selected heating time or heating temperature [A].
Display
Indication
t
Time in minutes
°C
Temperature in degrees Celsius
°F
Temperature in degrees Fahrenheit
12
UP
MODE
DOWN